Radiation Exposure due to CT of the Scaphoid in Daily Practice
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Study background: The aim of this study was to measure radiation exposure including scatter radiation, resulting from CT of the scaphoid in different settings as used in daily practice and to calculate the effective dose (ED) using a wrist phantom. Methods: The radiation exposure was quantified for five different CT protocols, all used in daily practice for the scaphoid CT. Two protocols concerned a CT of the scaphoid with a plaster cast of the hand and three protocols without. For all protocols the Computed Tomographic Dose Index weighted (CTDIw), the scatter dose to the brain and scatter dose to the torso were derived from the CT and measured externally with the Piranha dose meter. Results: The average CTDIw was 2.18 mGy. The average scatter to the brain and torso was 0.011 mSv. The average estimated ED was 0.02 mSv (range 0.02 to 0.04) of which 0.0008 mSv (range 0.0003 to 0.0012) was due to the scatter radiation. The two CT protocols of the scaphoid performed with a plaster cast resulted in a 90% higher ED, although the power of the study was too low to demonstrate this statistically. Conclusion: The CT protocols used for scaphoid analyses in a plaster cast immobilized hand may result in higher radiation exposure than without plaster cast. We therefore recommend, whenever possible, performing CT of the hand and wrist without a plaster cast.
Ask about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Similar by topic
Conference abstract · 14 Jul 2016
Determination of alpha radiation dose to skin due to the application of different radiopharmaceuticals
Conference abstract · 3 Aug 2015
Radiation Workers Dose Analysis in Medical Practices at Hamad Medical Corporation in Qatar
Conference abstract · 3 Aug 2015
The establishment of local DRLs for ERCP – a practical tool for the optimization of patient radiation doses and for quality assurance management
Editorial · 31 Aug 2024
Reducing Radiation Exposure Innovations and Techniques in Safe Imaging Practices
More from this journal
The newest in Nuclear Medicine & Radiation Therapy.
Opinion · 1 Dec 2025
Radiolabeled Antibody Conjugates: Targeting Cancer Resistance
Brief report · 1 Dec 2025
AI: Precision Radionuclide Therapy Dosimetry Advancements
Brief report · 1 Dec 2025
Multi-Isotope Therapy: Powering Precision Nuclear Oncology
Conferences in this field
Upcoming conferences in this field.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalNuclear Medicine & Radiation Therapy
- SubjectRadiology & Imaging
- SubjectEnergy & Power
- BylineArticles whose byline prints “Andele D. de Zwart”
- BylineArticles whose byline prints “Frank J.P. Beeres”
- BylineArticles whose byline prints “Mike Pillay”
- BylineArticles whose byline prints “Lucas M. Kingma”
- BylineArticles whose byline prints “Inger B. Schipper”
- BylineArticles whose byline prints “Steven J. Rhemrev”