Scholars Central

Research articlePublished 2014

Microdialysis: Reducing the Delay in Detection of Shift in Molecular Composition a Laboratory Study

Authors: Rauff-Mortensen Andreas, Kirkegaard Hans, Birke-Sørensen Hanne

Transplantation Technologies & Research

Volume 4 · Issue 1 · Pages 1–4

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Introduction: Microdialysis is one of the methods used clinically for the detection of ischemia. Although microdialysis is reliable, in most clinical settings there is a delay of 1-2 hours before the information is available. Objective: The aim of this study was to evaluate whether an increase in the Microdialysis per fusion rate from 0.3 to 1.0 or 2.0 μl/min was capable of reducing the delay in the detection of a shift in molecular composition. Methods and material: Microdialysis was performed in a container with 3 catheters per fused with 0.3, 1.0 and 2.0 μl/min. The molecular composition in the container regarding glucose and lactate was initially as follows: CGlucose=6.0 mmol/L and CLactate=2 mmol/L. At T=90 min the composition was changed to CGlucose=1 mmol/L and CLactate=12 mmol/L. Dialysates were harvested from the three catheters and were analysed regarding the concentration of glucose and lactate. For calculation of the relative recovery, samples were harvested directly from the liquid. The relative recovery and the delay before new steady state were calculated for each of the 3 catheters. The experiment was performed 8 times. Results: A decrease in relative recovery was found with the higher perfusion rate. For glucose, the relative recovery was 100, 88, and 69% at perfusion rates of 0.3, 1.0 and 2.0 μl/min. For lactate, the corresponding values were 103, 93, and 77%. An increase in the lactate/glucose ratio was found with the higher perfusion rate. The delays in detection of shift in molecular concentration were found to be 60, 20, and 10 minutes for catheters 0.3, 1.0 and 2.0, respectively. Conclusion: Using microdialysis it is possible to significantly reduce the delay while still detecting a shift in the concentration of glucose and lactate when the perfusionrate is increased.

Subjects

Surgery

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

More from this journal

The newest in Transplantation Technologies & Research.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalTransplantation Technologies & Research
  • SubjectSurgery
  • BylineArticles whose byline prints “Rauff-Mortensen Andreas”
  • BylineArticles whose byline prints “Kirkegaard Hans”
  • BylineArticles whose byline prints “Birke-Sørensen Hanne”

For authors and organisers

Publish, present and keep up with your field

Find the right journal for your paper and submit your manuscript.

Photo: Pexels