Research article · 30 Jan 2018
Conference abstractPublished 26 May 2023
Endoscope reprocessing: Future has already started
Pentax medical EMEA, Germany
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
In todays medical world flexible endoscopes are important medical devices for diagnose and treatment of various medical diseases. Although sterile single use flexible endoscopes have been introduced, most flexible endoscopes are still reusable. As reusable flexible endoscopes are defined as semi-critical devices. After each use reprocessing of the flexible endoscope is needed to have a clean and safe endoscope for the subsequent paptient. The reprocessing process is a multi-step process, consisting of several steps from bedside cleaning to high level disinfectioen, which must all be performed consequently. Although some steps are done manually, last decades many improvements have been made to improve the reprocessing process, like automated endoscope reprocessors and drying cabinets. Even with the introduction of an automated endoscope reprocessor, the manual cleaning should never be neglected to guarantee a successsful next disinfection step. Many studies have indicated human factors as a risk in successful manual cleaning. Also many studies indicate not all health-care facilities dry their endoscopes after reprocessing in a sufficient way or do not dry them at all. So it is challenging to look for improvements and new techniques challenging to optimize reprocessing, minimizing the risk of infection and maximizing patient safety, espacially related to the manual cleaning step and drying and storage. Recently three novell techniques are introduced to improve the reprocessing process. The first one is a device that is an automated alternative to classical brushing and flushing. It will standardize the cleaning process, without the use of brushes and chemicals. The secondo ne is an alternative to the traditional drying- and storage cabine. Using an unique airflow technique, endoscope channels are dried in only a few minutes. Storing the endoscope afterwards in a special bag and inflating some ozone, the endoscope can be stored under dry, dust free, and aseptic conditions up to 31 days. Finally the third one, is an automated disinfection device that will channel-less endoscopes and TEE probes in only 60 seconds. Introducing these novell techniques and products, infection risks will be minimized, workflow effciency will be improved, and – most important – patient safety will be maximized. When it comes to modern endoscope reprocessing, the future has already started.
Subjects
Infectious DiseasesAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Similar by topic
Conference abstract · 4 Jan 2017
Ambulatory colorectal disease: A vision for the future or already here?
Conference abstract · 2017
The role of Staphylococcus aureus, related bacteria and their virulence factors in pathogenesis of multi organ infections: Future molecular targets in prevention and treatment, in addition to already available antibacterial drugs
Conference abstract
Green packaging and green tea: A solution already industrially achievable and its future developments
Editorial · 29 Jan 2025
Safeguarding the Start of Life: Advancing Neonatal Health for a Healthier Future
More from this journal
The newest in Clinical Infectious Diseases: Open Access.
Brief report · 29 Dec 2025
Infection Control and Public Health: Integrated Strategies
Brief report · 29 Dec 2025
Preventing MDROs in ICUs: A Comprehensive Approach
Commentary · 29 Dec 2025
Combating Multidrug-Resistant Organisms: A Multilayered Approach
Conferences in this field
Upcoming conferences in this field.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalClinical Infectious Diseases: Open Access
- SubjectInfectious Diseases
- BylineArticles whose byline prints “Paul J Caesar”

