Scholars Central

Conference abstractPublished 24 Oct 2022

Trace metals analysis in electronic cigarettes formulations using atomic spectroscopy techniques

Authors: Abdulaziz Al-Mantashari

Umm Al-Qura University College of Science, Saudi Arabia

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Background and objective: Electronic cigarettes (ECs) are battery-powered devices that convert liquid into an aerosol (suspension of liquid or solid or both in the gaseous state) that can be inhaled. The amount of aerosol generated can be affected by many factors including device settings, puff volume and duration. Heavy metals pose high health risk ones administered to human body at high concentrations. As electronic cigarettes are used wildly these days therefore it is important to ensure that they do not contain high level of heavy metals in their formulations. The research goal of this study is to quantify the concentration of heavy metals in the liquid of E-cigarette using Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Methods: Five samples of E-liquids were purchased from the market in Saudi Arabia to quantify the level of heavy metals. Two methods were used to prepare E- liquids. First method was preparing E-liquids directly from its bottle while other method was placed E-liquids in E- cigarette's device for 20 puffs. In both methods weighed 0.2g into digestion vessel then 2 mL of deionized water and 5 mL of nitric acid were added before place digestion vessels into the microwave. All metals were quantified using Inductively coupled Plasma Mass Spectrometry (ICP-MS). Results: The average concentration of five different samples were quantified for cadmium (Cd), lead (Pb), arsenic (As), mercury (Hg), Chromium (Cr), Tin (Sn) and Copper (Cu) in the first method were 0.963, 6.698, 11.845, 12.390, 0.000, 5.932 and 5.654 μg/l, respectively. On the other hand, the concentration in the second method for cadmium (Cd), lead (Pb), arsenic (As), mercury (Hg), Chromium (Cr), Tin (Sn) and Copper (Cu) were 0.114, 131.853, 12.184, 7.480, 154.042, 134.189 and 442.980 μg/l, respectively. Conclusion: Our data suggest that e-cigarettes could be a source of harmfulmetal exposure ( Pd , Cr , Sn and Cu) the tank samples had higher amounts , indicating that coil contact caused E-liquid contamination.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

Similar by topic

More from this journal

The newest in Medicinal Chemistry.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalMedicinal Chemistry
  • SubjectChemistry
  • SubjectPharmaceutical Sciences
  • BylineArticles whose byline prints “Abdulaziz Al-Mantashari”

For authors and organisers

Publish, present and keep up with your field

Find the right journal for your paper and submit your manuscript.

Photo: Pexels