Research article · 23 May 2022
Conference abstractPublished 21 Sep 2022
Zero fluoroscopy catheter ablation: Single center experience
Lancashire Cardiac Centre, Victoria Hospital, Lancashire UK.
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Background: Radiofrequency catheter ablation for cardiac arrhythmias has traditionally been guided by fluoroscopy. Exposure to fluoroscopy has no safe dose void of stochastic and deterministic biologic risks. Zero fluoroscopy (ZF) approach for electrophysiologic (EP) studies and catheter ablation is gaining interest as a means of eliminating the above risks. Here we share our single tertiary centre experience in ZF EP procedures. Methods: A prospective non-randomized registry between January 2021 to December 2023 is being performed. Consecutive patients with supraventricular tachycardia, including AVNRT, AVRT Aflutter are being enrolled. Ensite Precision (Abbott ), Carto (Biosense Webster) and Rhythmia (Boston Scientific) 3D electroanatomic mapping systems are being used. Cath lab staff members are void of wearing heavy lead protection during the procedure. Outcomes sought include acute procedure success, complications, procedure times and fluoro exposure. Since more operators utilized conventional fluoroscopy (CF) approach, the sample ratio of ZF to CF was about 1:3. Results: Between February 2021 to November 2021, a total of 40 ZF cases are described. There were no significant differences in both acute procedural success and complication rates. Total procedural time was initially longer in the ZF series with the learning curve which attenuated following the first 5 to 7 cases. Number of lesion applications although not reaching statistical significance in this series were generally lower in the AVNRT cohort. Overall subjective assessment of the patient journey and cath lab team experience in the ZF series is a positive given being lead free for staff members and radiation exposure free for both patient and staff cohort. Conclusion: Peri-procedural and post-procedural outcomes with a ZF approach compares favourably with traditional fluoroscopic navigation without increasing procedural times. With increasing data and evolving mapping technologies potentially offering lower cost, zero fluoro catheter procedures has the potential to become the default approach when starting an EP procedure.
Subjects
CardiologyAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Similar by topic
Research article · 17 Oct 2016
Radiofrequency catheter ablation of ventricular tachycardia in structural heart disease: single team experience with follow-up upto 5 years
Review article · 30 Jun 2020
The Catheter ablation of cardiac arrhythmias in pregnancy with limited fluoroscopy
Research article · 2020
Catheter ablation of cardiac arrhythmias in pregnancy with limited fluoroscopy
Perspective · 12 Apr 2025
Zero Contrast BAP Treatment Guided by Real-Time Fusion of CT Angiography with X-Ray Fluoroscopy: A Novel BPA Technique
More from this journal
The newest in Cardiovascular Diseases & Diagnosis.
Article · 19 Feb 2026
When Myxoma Meets Bicuspid Aortic Valve: A Rare and Unexpected Cardiac Association
Brief report · 29 Dec 2025
AI Transforms Cardiology: Diagnosis to Personalized Care
Brief report · 29 Dec 2025
Minimally Invasive Cardiac Surgery: Advancements and Outcomes
Conferences in this field
Upcoming conferences in this field.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalCardiovascular Diseases & Diagnosis
- SubjectCardiology
- BylineArticles whose byline prints “Dr. Aruna Arujuna”