Laboratory of Microfabrication , National Nanotechnology Laboratory , National Center for Research in Energy and Materials, Campinas , Sao Paulo, Brasil; Instituto of Chemistry , State University of Campinas, Campinas, Sao Paulo, Brasil; Instituto National Science and Technology Bioanalytics, Campinas, Sao Paulo, Brasil

Journal of Analytical & Bioanalytical Techniques

Volume 6 · Issue 5 · Pages 1–7

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

The outcomes described herein outline the potentiality of the microemulsification-based method (MEC) for development of rapid testing (point-of-use) technologies. MEC was recently proposed by these authors for analytical determinations wherein the detection is conducted in solution with naked eyes. It relies on effect of analyte over the colloid thermodynamics by changing the minimum volume fraction of amphiphile needed to generate microemulsions (MEs) (ΦME), which represents the analytical response of the method. We report in this paper the successfully coupling of MEC-based detection with gas diffusion separation. Such result extends the field of application of MEC in analytical sciences by improving its selectivity. One custom-designed module was constructed on PTFE for the separation measurements. It was utilized in combination with MEC for determining water in ethanol fuels using water/ n-propanol/oleic acid MEs and water-rich compositions. In this situation, accurate direct determinations by MEC are not possible. In addition, further studies on analytical performance and robustness of MEC by using n-propanol amphiphile are described. The method was robust as regards to deviations in dispersion preparing and changes in temperature. Concerning the analytical performance, the analytical curves presented wide linear range with limits of linearity of up to 70.00% v/v ethanol to water (ΦE). The limits of detection (S/N=3) were of 1.03%, 7.21%, and 0.68% v/v ΦE for compositions with water- (region A) and oil-rich (region C) domains as well as equal volumes of water and oil phases (region B), respectively. With respect to the regions A and B, the analytical performance stressed herein exhibited best linearity and comparable sensitivities when compared to these levels reached with ethanol amphiphile (our first publication on MEC) rather than n-propanol.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

Similar by topic

More from this journal

The newest in Journal of Analytical & Bioanalytical Techniques.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Analytical & Bioanalytical Techniques
  • SubjectBiochemistry & Biotechnology
  • SubjectChemistry
  • BylineArticles whose byline prints “Gabriela Furlan Giordano”
  • BylineArticles whose byline prints “Karen Mayumi Higa”
  • BylineArticles whose byline prints “Adriana Santinom”
  • BylineArticles whose byline prints “Angelo Luiz Gobbi”
  • BylineArticles whose byline prints “Lauro Tatsuo Kubota”
  • BylineArticles whose byline prints “Renato Sousa Lima”

For authors and organisers

Publish, present and keep up with your field

Find the right journal for your paper and submit your manuscript.

Photo: Pexels