effect of each analytical parameter in the final analysis results. Seven analytical factors were selected and small variations were induced in the nominal values of the method. Then, 8 runs ... final result. The 7…
Asimple, rapid, selective and precise RP-HPLCmethodwas developed for estimation of lami vudine in tablet dosage form. Eurosphere-100 C18, 250ï‚´4.6mm, 5ïÂÂmparticle size column, in isocraticmodewithmobile…
biglobosa and its fractions designated PF1-PF4 were investigated in mice and against selected diarrhoea-causing micro-organisms. The oral median lethal dose (LD50) of the extract in mice ... estimated to be greater than…
treat all mistakes equally; therefore, selections of specific frequent mistakes have been presented. The error analysis was created on a grid consisting of four columns. The number of mistakes
required special types of C18 columns, or had long run times. A Design of Experiments (DoE) approach targeting the shortest run time with greatest selectivity was adopted using a user
using symmetry C18, 5.0 mm column was developed for the determination of Efonidipine Hydrochloride Ethanolate (EFD). The mobile phase acetonitrile and water ratio was selected 85: 15 via flow rate
material was found to be selective for Pb(II) ions. Some analytically important binary separation of the metal ions has been achieved on the column of this composite. This composite
wavelength 241 nm was selected for the determination of repaglinide. RP-HPLC analysis was carried out using Agilent TC-C18 (2) column and mobile phase composed of methanol and water
within 5 min run time. The stationary phase was conventional C18 column (250 x 4.6 mm, 5 μm). The detection was carried out at UV wavelength ... respectively. The calibration curve was linear for the selected range with…
endocrine disrupter bisphenoi-A (BPA) in blood. Electro chemical detection was used for selective and sensitive detection of BPA. Determination of BPA in the blood of uremia patients treated ... suppress the ionization…
chromatography, S2D-LC. LC-LC methods are well robust and experimentally feasible. Their separation selectivity is very high and sample recovery is reasonable. LC-LC can in one single step ... sample constituents can be…
spontaneous fermentation (without addition of starters). Of 220 lactic acid bacteria strains randomly selected from such products, 12 isolates capable of producing bacteriocin-like substances (bac+) were detected. Based…
quantification of zolmitriptan. The liquid chromatographic separation was performed with Symmetry C18 packed column (3.5 μm, 2.1 × 50 mm) using a mixture of Acetonitrile-Water-Formic acid ... Detection was performed on…
environment widely. This study was to develop and validate a simple, rapid and selective determination method of PFOA, PFOS and PFHxS for rat plasma and tissue. The analytes and internal ... liquid extraction after…
column and a mobile phase of phosphate buffer: methanol: triethyl amine (60: 40; 0.2 by volume). The forth method was a thin layer chromatography coupled with densitometric detection. Selective quantification
simple, precise, rapid, selective, and economic reversed phase high-performance liquid chromatography (RPHPLC) method has been established for simultaneous analysis of Metformin hydrochloride and Rosuvastatin in bulk…
provide confirmatory identification, structural interpretation, and higher sensitivity in complex matrices. With its unique selectivity, IC has been successfully applied to the identification and quantification of…
separating columns which are known to be sensitive, hence leading to imprecise and inaccurate results during bio-assaying. To address these challenges, our lab synthesised a novel, selective, effective
most frequently used of this group. In this study fluoxetine and sertraline as selected model molecules from antidepressant active agent, which have environmental as well as pharmacological and biological importance…
HLPC, the analytical column HILIC-ZIC® from ES Industries (West Berlin, USA) was used. The parameters analyzed for analytical validation were specificity/selectivity, linearity, LD, LQ accuracy, precision (repeatability
Xterra-(150x4.6mm, 5µ) column. Then the mobile phase containing a mixture of Ammonium acetate buffer (pH 10): ACN 70:30 % v/v was selected at a flow rate
week by opening the column in order to remove adherent scale deposits. To solve this problem, tests and experiments were held in order to select an own crude oil emulsion
acetonitrile, circulating in a column of Wakosil C18 HG (250 mm x 4,6mm; 5 μm) at 20 ° C. Firstly, a specificity and a selectivity for INH and PZA have
simple and selective LC method for the quantitative estimation of Balsalazide in capsule dosage form. Chromatographic separation was achieved on a c18 column using Inertsil ODS 3V column, C18 (250x4.6
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.