simple, rapid, accurate and precise densitometric method for determination of cefixime trihydrate and ornidazole in combined tablet dosage forms has been developed and validated. The separation was achieved on Merck…
selective and sensitive high performance thin layer chromatographic method for the determination of voriconazole in human plasma is developed and validated. After precipitation of plasma proteins with acetonitrile, the…
simple, selective, accurate reverse phase - high Performance Liquid Chromatographic (RPHPLC) method was developed and validated for the analysis of Lopinavir in bulk drug. Chromatographic separation achieved…
simple selective high performance liquid chromatographic (HPLC) method was developed and validation for the analysis of omprazole magnesium trihydrate (ES) in tablets. ES was subjected to neutral, acid and alkali…
Simple, selective, rapid, precise and economical reverse phase HPLC method has been developed and validated for the Quantitative Estimation of Rimonabant in pharmaceutical preparation. Isocratic separation was…
Acetic acid are 3.03, 6.20, 6.87, 10.27, 14.57, 17.49 &19.54 respectively. The method was validated as meets the all regulations of System suitability, Specificity, Method Precision, Linearity, LOD & LOQ, Precision
absorbance and x is the concentration of the pure drug solution. The method was validated for several parameters like accuracy and precision. The values of relative standard deviation and % recovery
retention time of valsartan was found to be 2.530 minutes. The method was validated for system suitability, precision, accuracy, linearity, robustness. The linearity range for Valsartan was found ... method is validated…
correlation coefficient value 0.999 and 0.998 at 284nm and 271nm respectively. The present method was validated as per ICH guidelines. The result obtained of this method were in good agreement
methods (r2=0.9996 for method A and r2=0.9995 for method B). The results of an alysis have been validated statistically, which confirm the accuracy and reproducibility of the methods
simple and accurate methods to determine rosuvastatin calcium (ROS) and ezetimibe (EZE), in combined dosage form, were developed and validated using liquid chromatography (LC) and densitometric-thin layer chromatography…
isocratic chiral stationary phase high-performance liquid chromatographic (CSP-HPLC) method has been developed and validated for the quantitation of (S)-isomer in Alogliptin Benzoate. Separation was achieved with…
time taken and amount of solvent consumed for each analysis. The method is validated and successfully applied to the simultaneous determination of Bromhexine and Ciprofloxacin in bulk and pharmaceutical formulations
range of 10- 30 mg/ml for Enalapril Maleate and Hydrochlorothiazide. The method was validated according to the guidelines of International Conference on Harmonization (ICH) and was successfully employed
Ofloxacin were found to be 0.16 - 0.49 μg/mL respectively. The validated optimized method for analysis of Cefixime and Ofloxacin as per ICH Q2B guidelines ... found to be simple, precise and reproducible. Undoubtedly…
retention time was observed at 7.33 min. The method was validated with respect to system suitability, linearity, precision, accuracy, limit of detection (LOD), limit of quantification (LOQ) and robustness. Linearity…
generated result is done by taking six replicates of the run. Finally the method was validated as per ICH Q2 guidelines. QbD approach is successfully applied for HPLC assay method
rapid, accurate and precise reverse phase-high performance liquid chromatographic (RP-HPLC) method has been developed and validated for the simultaneous determination of Terbutaline sulphate and Guaiphenesin in combined…
High performance thin layer chromatographic (HPTLC) method has been developed and validated for simultaneous investigation of Irbesartan and Hydrochlorothiazide in tablet formulation. Chromatographic separation was…
column, with shorter run time 11 minutes. Method validation parameters such as specificity, linearity, precision, accuracy, determination of LOD and LOQ and robustness were evaluated as per ICH guidelines ... validated…
simple, efficient, and robust stability-indicating RP-HPLC method has been developed and validated to measure Lamivudine, Zidovudine and Nevirapine at a single wavelength (268 nm) in order to assay
simple, specific, accurate and precise reverse phase high performance liquid chromatographic method was developed and validated for the estimation of Lincomycin in tablet dosage form. An Inertsil ... retention time for…
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.