form. The method developed produced high sensitivity, precision and accuracy. An isocratic C18 (150 x 4.6 mm, 5μ) column was used with mobile phase of composition Methanol : Water ... ratio of 65:35 v/v and 1.0 mL/min…
accurate, simple, sensitive and precise stability indicating isocratic, reversed phase liquid chromatographic (RP HPLC) method was developed and validated for the determination of Bosentan in bulk and pharmaceutical…
boric acid because boric acid could not be detected by UV detector as it does not contain chromophore group. The reverse phase HPLC analysis was carried out on isocratic system ... phase consisted of water: acetonitrile…
simple, rapid, and sensitive RP-HPLC method was developed and validated for the simultaneous determination of degradation impurity of Noscapine HCl. The method was developed to determine Papaverine in Noscapine…
column and mobile phase of composition Acetonitrile : Water in the ratio of 80:20 v/v at a flow rate of 0.8 mL/min with UV detection ... Estradiol valerate in their dosage forms. The proposed method is accurate…
Formulations. Formulations was developed and validated in the present study. The mobile phase consists of mixed acetonitrile and water in the proportion 50:50 respectively. And this was found ... accuracy, precision…
simple, reliable, sensitive, precise, rapid, and reproducible RP -HPLC method was developed and validated for the determination of Paroxetine in pharmaceutical dosage form. Separation was achieved under optimized…
using phosphate buffer pH 3.0 and acetonitrile as mobile phases A & B respectively. Wavelength for UV detection: 220nm, flow rate: 1.0ml/min and Injection volume: 10μl. The performance ... detection robustness and…
phase composed of 0.1% Perchloric acid, Acetonitrile (80:20v/v) at a flow rate of 1.1 mL/min. The column temperature was maintained at 30°C and the detection ... Validation parameters such as system suitability…
bulk drugs. The validation parameters include system suitability, specificity, accuracy, precision, linearity, limit of detection and limit of quantification. In addition to this, the stability of main drug has also…
simple, precise and accurate Spectrophotometric and RP-HPLC method with enhanced sensitivity for the determination of the antidepressant paroxetine (PXT) in bulk and its dosage forms. The drug showed good ... Phosphate…
achieved with the Altima C18, (150 × 4.6 mm 5μm) column with a mobile phase used a mixture of acetonitrile and KH2PO4 (60:40, v/v %). The temperature of the column ... axitinib it’s highly sensitive towards acid, base…
solvent and detection was done at 235 nm. The HPTLC method was performed using Pre-coated silica gel G60 F254 plate using the mobile phase chloroform, methanol and ammonia ... developed methods are precise. When…
mobile phase composed of ortho phosphoric acid buffer, Acetonitrile, (50:50v/v) at a flow rate of 1mL/min. The column temperature was maintained at30°C and the detection ... correlation coefficient for Darunavir and…
sensitive rapid Gas Chromatography with mass spectrometry (GC-MS) method has been developed and validated for the determination of 1-Bromopropane content in Divalproex sodium drug substance. 1-Bromopropane ... potential…
simple, sensitive, and rapid HPLC method was developed for analyzing H1 receptor blockers viz, hydroxyzine, cetirizine, meclizine, loratadine, desloratadine, rupatadine and fexofenadine in bulk and drug products…
simple, specific, sensitive, precise, and accurate high performance liquid chromatography method was developed for the determination of Epinephrine in pharmaceutical injection forms. Epinephrine is a catechol (C6H6O2)…
sensitive and selective HPLC method for the determination of levofloxacin in rat plasma is developed and validated. Separation is done on a Phenomenex C18 RP column with a mobile phase ... acetonitrile – 0.4 %…
rapid and sensitive capillary electrophoresis (CE) method was developed for the determination of formic acid and acetic acid content in Cephalosporin drugs using a background electrolyte (solution containing ... 40cm…
great potential to full-fill requirements for the bio signature detection. Such instrumentation combining high resolution imaging with very sensitive chemical analysis of planetary materials can be used ... experimental…
Current study defined FLOT1 as a novel serum biomarker of OC, improving the diagnostic sensitivity and accuracy, and to determine FLOT1 expression in human ovarian tumors and its effect ... with OC measured by ELISA…
steps. An ideal pretreatment procedure should be simple, cost effective, environmental friendly and compatible detection method. There are two fundamental goal of pre-treatment procedures; separation of matrix…
rapid, specific, validated and sensitive method. An isocratic separation is achieved using Phenomenex C18 (75 x 4.6 mm, 2.6 μ, 100 Å) with mobile phase comprised of water: acetonitrile ... time of 2.71 min at 1 mL/min…