standard (Naproxen) were extracted by using solid-phase extraction technique with direct elution. The resolution of peaks was achieved with 10 mM potassium dihydrogen phosphate buffer ... less than 12.5 min. The method…
eluents were monitored at 280 nm. The calibration curves were linear over the range of 2 – 20μg/ml for Lornoxicam and 10 – 20 μg/ml for Paracetamol. The average retention ... respectively. The method was reproducible…
chromatographic conditions and finally , the most usual scenario is to hardly get baseline resolution but with relatively low enantioseparation factors. Strongly overlapped chromatographic profiles of ofloxacin…
have attracted considerable interest in recent days due to their immense potential in wide range of applications as biological fluorescent labels, bio imaging, light emitting diodes, solar cells ... structure…
investigated by several techniques including microstructure characterizations using scanning electron microscopy (SEM), high resolution transmission electron microscopy (HR-TEM). Then subjected to X-ray diffraction…
investigated by several techniques including microstructure characterizations using scanning electron microscopy (SEM), high resolution transmission electron microscopy (HR-TEM). Then subjected to X-ray diffraction…
column effluent was examined by using UV detector at 205 nm. Resolution between S-(+)-Epichlorohydrin (SE) and R-(-)-Epichlorohydrin (RE) was found to be ≥ 5. The method was authenticated ... detector response for RE…
retention times were discerned as 1.76, 2.11 min and the linearity range was covered from ... pure drugs were found to be capable of giving swift retention times with fine resolution than that achieved with conventional…
Separation of both Atorvastatin and Ezetimibe was achieved with in 5 minutes with required resolution, accuracy and precision thus enabling the utility of the method for routine analysis. Chromatographic separation…
Drotaverine hydrochloride, domperidone and paracetamol were separated in less than 10 min with good resolution and minimal tailing, without interference of excipients. The method was validated according to ICH…
detector was set at a wavelength of 254 nm. The resolution between paracetamol and piroxicam was less than five. Developed method was extensively proved to be robust for the titled ... piroxicam was 0.9986 and 0.9990…
Resolution of Candesartan cilexetil was greater than 2.0.The drug was subjected to forced degradation such as photochemical oxidation, chemical oxidation, acid hydrolysis, base hydrolysis, different pH range, aqueous &…
acid in the mobile phase enhanced chromatographic efficiency and resolution between the isomers. The resolution between the isomers was found to be more than three. The developed method was subsequently ... respectively…
from its precursor D-Glucal (DGL) and starting material D-Glucose (DGS) with resolution > 3.0. ELSD parameters such as nebuliser temperature and impactor position were found to be critical while ... flow rate 1.5 mL/min…
evaluation of Octopamine in bulk and formulations was developed and validated. The Chromatographic resolution of Octopamine was achieved by using Acetonitrile: 0.01M Potassium phosphate (Ortho phosphoric acid ) Buffer…
accurate RP-HPLC method for the estimation of Fexofenadine in Bulk and Tablets. The resolution of drug was achieved on Symmetry C18 (150mm x 4.6mm i.d., 5mm particle size ... retention time of 3.399 min, respectively…
rapid, sensitive, precise and economical along with excessive resolution RP-High Performance Liquid Chromatographic method for determination of Amoxicillin and Carbocisteine has been developed. The chromatography system…
degradation (70°C reflux). Good resolution between the peaks corresponds to degradation products. The calibration curves of Nabumetone showed good linearity in the concentration range 2 –100 μg/ml with
respectively with resolution of 3 .1 a nd 6.8. Linearity was established for Emtricitabine, Tenofovir Disoproxil Fumarate and Rilpivirine in the range of 50-300μg/ml for Emtricitabine
There was good resolution observed between Noscapine and Papaverine Peak which is about 2.8. The proposed method exhibited excellent linearity over the concentration ranges
Water (70:30) was used as mobile phase .It showed sharp peaks and good resolution (column-Grace smart RP 80 (250×4.5Mm) 5μm), (HPLC PU – 2080 Plus, Jasco ... showed λmax at 382 nm. The method obeys Beers-Lamberts law in…
range from 97.1% to 103.0%. Limit of quantitation for all 12 solvents were sufficiently lower than limits specified by ICH. In the proposed method, USP resolutions between
phase system containing n-Hexane, ethanol and n-butyl amine (90:10:1). The resolution between enantiomers was found to be more than 2.0. The retention times of S-enantiomer ... found to be 99.9%.Correlation coefficient…
diffraction. The crystalline perfection is quite good as observed from the high resolution X-ray diffractometry. The FTIR spectrum gives the detail about the various functional groups present ... studies show that the…
meant to examine the effectiveness of joint inversion of refraction tomography and high resolution 3D seismic reflection survey in locating the best point of aquifer within the basement complex ... average velocity…
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.