X104 L/mol/cm and 0.0323μg/cm2 respectively. The limit of detection and quantification were 0.28μg/ml and 1.30μg/ml respectively. The intra and interday precision
Linearity and Range, Accuracy, Precision, Specificity, Limit of Detection (LOD), and Limit of Quantification (LOQ). The method also has been successfully applied for analyzing of two brands of tablet marketed
study was to assess the iron and folic acid in cabbage (Brassica oleracea). The quantification of both the folic acid and iron was done by BLC-20 liquid chromatography
with different parameters such as Linearity, Precision, Repeatability, Limit of Detection (LOD), Limit of Quantification (LOQ), Accuracy, Robustness and Ruggedness. Results: Canagliflozin in methanol shows maximum…
validate an efficient Reverse Phase High Performance Liquid Chromatography (RP-HPLC) method for quantification of β-asarone from rhizomes of A. calamus of the wild and marketed variety and also
Tablets). The zero crossing point of Paracetamol (247.42 nm) has been selected for the quantification of Lornoxicam whereas the zero crossing point of Lornoxicam (233.28 nm) has been selected ... quantification of…
epigenetic mechanisms regulating their expression is difficult. Hence, we examined a method for stable quantification of such GC-rich DNA sequences. Quantification of DNA during real-time PCR is often ... segments with…
present work, an HPLC-UV method was set-up to allow the simultaneous quantification of the reduced- GSH, oxidised-GSSG and nitroso-GSNO glutathione species. Chromatographic separation was achieved ... minutes. In-house…
state. If corrective standardized measures are implemented in the areas of procurement, drug quantification, distribution, and inventory control, then the problems associated with stock-outs and wastage can be minimized
Hydrochlorothiazide and Propranolol respectively. The limit of quantification was 0.158 μg/ml and 1.397 μg/ml for Hydrochlorothiazide and Propranolol. The accuracy of the method was found
statistically and by recovery studies. The LOD (limit of detection) and LOQ (limit of quantification) for visible spectra were found to be 5.88μg/ml and17.83μg/ml. The correlation
single laser excitation wavelength to excite the Raman spectra of all SERS nanotags, quantification using the fingerprint intensity of the corresponding SERS nanotags; high photostability and optimal contrast by using
single laser excitation wavelength to excite the Raman spectra of all SERS nanotags, quantification using the fingerprint intensity of the corresponding SERS nanotags; high photostability and optimal contrast by using
brain cells regeneration after MSCs transplantation to the brain of stroke rat models. The quantification of generated NO was based on the gas-phase chemiluminescent reaction between NO and ozone
potential for identification of dominant TOC-producing microorganisms. Further, a recently developed technique for quantification of TOCs (small stir bars with absorbing material) allows for detection of TOCs at small
total biomass. Lipids were extracted three times using three times chloroform/methanol. The quantification of phospholipids (РL) was performed by the content of inorganic phosphorus. Glycolipids (GL) and non-polar
carbon paste electrode. Then, the modified electrode was successfully applied in Ag+ ion quantification by potentiometric method. The results showed that the modified electrode exhibits a Nernstian slope
mobile phase with gradient elution. The flow rate was 1.0 mL/min and quantification was carried out using ultraviolet detection at wavelength 254 nm. The method was validated according
transfer capillaries are used which cause problems through contamination or even blockage. Therefore, no quantification or semi-quantification of decomposition products is possible. A new technique was established that
technique of choice for a variety of applications. Use of DESI for characterization and quantification of additives, contaminants and by-products in insulating liquids has been explored in our laboratory