Separation was completed within 4.62, 11.05 minutes respectively. The method was validated with respect to linearity, precision, accuracy, selectivity, specificity and ruggedness. The method was specific to drug and also
Reversed phase high performance liquid chromatographic method was developed and validated for the estimation of Olmesartan medoxomil in bulk and formulation. Selected mobile phase was a combination of phosphate buffer…
ratio of 80:20. Detection was performed with UV detector at 210nm. The method was validated with respect to linearity, precision, accuracy, and specificity according to ICH guidelines. The responses
correlation coefficient and relative standard deviation were 0.9999 and 1.62%. The developed method was validated by the analysis of reference materials certified by total blood
reflux disease. A simple, precise cost effective and stability indicating RP-HPLC method has been developed and validated for the determination of both Naproxen and Esomeprazole in pharmaceutical compositions…
simple, ecofriendly, economical and accurate absorption ratio method was developed and validated by using hydrotropic solubilizing agent (8M ammonium acetate solution) for the determination of valsartan and…
reversed-phase high-performance liquid chromatographic (RP-HPLC) method with UV detection was proposed for separation of pentoxifylline and its impurities from tablet dosage forms. The best separation was achieved…
cost effective spectrophotometric methods are developed and validated for quantitative determination of paracetamol (PCT) and promethazine hydrochloride (PMZ) in tablet dosage form. Method I is based on the simultaneous…
selective and sensitive spectrophotometric method for determination of Minoxidil has been validated by three simple, precise and economical UV methods have been developed for the estimation of Minoxidil in…
Spectrophotometry were selected to determine DKP and TCS, respectively in combined formulation. The methods were validated by following the analytical performance parameters suggested by the International Conference on…
found to be99.64 % and 98.98% for Sitagliptin phosphate and Metformin hydrochloride. The developed method was validated with respect to linearity, accuracy (recovery), precision and specificity. The results were…
orally prior to Paracetamol administration. Plasma concentration of Paracetamol was determined using a validated spectrophotometric method. Pharmacokinetic parameters were calculated using standard non-compartmental…
LAFU) and 6-30 μg/ml for Domperidone (DOM) for both methods. The methods were validated by following the analytical performance parameters suggested by the International Conference on Harmonization ... Lafutidine (LAFU)…
determined after correction for absorbance of MFA at 233 nm. The methods were validated by following the analytical performance parameters suggested by the International Conference on Harmonization (ICH). Beer ... both…
simple, precise, accurate, rapid and reproducible reverse phase high performance liquid chromatographic method was developed for estimation of Nitazoxanide in oral suspension formulation. The mixture of acetonitrile…
HPLC method was developed for selective and simultaneous determination of Guaifensen and Dextromethorphan HBr tablets 1200/60 mg. The chromatographic separation was achieved on a Acquity UPLC ... linearity, and…
Norfloxacin and Tinidazole respectively. The second method involves determination using the Multicomponent Mode Method; the sampling wavelengths selected are 273 nm and 319 nm over the concentration ranges…
reliable and sensitive isocratic stability indicating RP-HPLC method has been developed and validated for assay of Ezetimibe in tablets and for determination of content uniformity. An isocratic separation
respectively. The methods were validated as per ICH guidelines. Statistical analysis proved that the methods were accurate, precise, and reproducible for analysis of ATV and RTV in tablets. The wide
both the simultaneous equation and first order derivative methods respectively. The results of analysis have been validated statistically and by recovery studies. The utility of the developed methods has been
respectively. The results of the analysis were validated statistically and recovery studies confirmed the accuracy of the proposed method. The developed method has been successfully used for the simultaneous estimation
method was developed for quantitative estimation of tapentadol hydrochloride in pharmaceutical preparations. The method was validated according to ICH, FDA and USP guidelines with respect to accuracy, precision…