found to be 99.64 % and 98.97% for Ritonavir and Lopinavir. The developed method was validated with respect to linearity, accuracy (recovery), precision and specificity. The results were validated statistically
simple, specific, accurate, and precise reverse phase high performance liquid chromatographic method was developed and validated for the estimation of Capecitabine in tablet dosage forms. A Welchrom C18column having…
post-dose. Concentrations of mesalamine in plasma were analyzed by a validated LC-MS/MS method, with LLOQ 2 ng/mL for Mesalamine and 10 ng/mL for N-Acetyl
simple, specific, accurate, precise and reproducible method has been developed and validated for the simultaneous estimation of Rifampicin and Isoniazid in combined dosage form by UV Spectrophotometric method. UV…
respectively. The % assay of PML was found out to be 99.66%. The method was validated by determining its accuracy, precision and system suitability. The results of the study showed that
deviation in the tablets was found less than 2% for six replicates. The method was validated according to ICH guidelines with respect to linearity, precision, limit of detection, limit
zero order and first order derivative spectrophotometric method. All the proposed methods have been extensively validated as per ICH guidelines. There was no significant difference between the performance
validity, composition, effectiveness and safety of the drug used. In this study physio- chemical analyses were done on some of the compound. SEM, EDX, FTIR and ICP methods were followed
validity, composition, effectiveness and safety of the drug used. The present study deals with the physio- chemical analyses of Rasapathagam. SEM, EDX, FTIR and ICP methods were followed to analyze
were 5.83, 7.27, 8.41 and 10.57min respectively. The method was validated according to the ICH guidelines. The validation characteristics included accuracy, precision, linearity, range, specificity, limit of…
develop a simple, accurate, precise and rapid UV second order derivative spectrophotometric method with subsequent validation by using ICH guidelines for the determination of ofloxacin and ornidazole by using ... found…
marker was 520 nm after derivatization with anisaldehyde sulphuric acid reagent. Proposed HPTLC method was validated according to ICH guideline. The retention factor of withaferin A, ursolic acid and stigmasterol…
Method II). Beer’s law is obeyed in the concentration range 20.0 – 80.0 μg ml−1. The optimum experimental parameters for the reactions have been studied. The validity
simple, rapid, accurate and precise chemo metrics assisted RP-HPLC method was developed, optimized and validated for the simultaneous estimation of the domperidone and ilaprazole in pure and pharmaceutical formulation…
rapid UV spectrophotometric, area under curve (AUC), method for simultaneous estimation of amoxicillin and carbocisteine from combined dosage form. The validation was carried out by using ICH guidelines ... found to be…
stepwise variable selection knearest neighbor molecular field analysis approach; a leave-one-out cross validation method. The developed model showed satisfactory statistical significance r2 (Regression) with 0.75 and q2…
within a range of 98-102% for both Gld and Ldpn. The developed methods were validated with respect to linearity, accuracy (recovery), and precision. The results were validated statistically
water and acetonitrile (50:50% v/v) was used as a diluent. The method was validated for system suitability, linearity, accuracy, precision, robustness, stability of sample solution. The method
passing, indicates that all degradents are separated from the analyte peaks. The developed method was validated as per ICH guidelines with respect to Specificity, Linearity, Accuracy, Precision, Limit of quantification
insecticide. A simple and rapid reverse phase high-performance liquid chromatographic method using UV detection was developed and validated for the analysis of chlorpyrifos in selected vegetable samples like cabbage…
with photo diode array detector as per international conference on harmonization guidelines. The analytical method validation was compared with high performance liquid chromatography with ultra violate detector…
water and acetonitrile (50:50% v/v) was used as a diluent. The method was validated for system suitability, linearity, accuracy, precision, robustness, stability of sample solution. The method
Emtricitabine indicated that all degradents are separated from the analyte peak. The developed method was validated as per ICH guidelines with respect to Specificity, Linearity, Accuracy, Precision, Limit of detection
Column temperature, sampling rate 5pts/sec at 230nm. The method was validated for specificity, reproducibility, accuracy, linearity, robustness and solution stability and can be used for the assessment of quality
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.