Analysis of Ursodeoxycholic Acid concentrations was performed using a validated liquid chromatography with tandem mass spectrometry (LC-MS/MS) method. The pharmacokinetic parameters including Cmax, AUC0-t, AUC0-inf, Tmax
precise, reproducible, accurate and consistent with minimum or rather negligible deviations. We have validated the method which determines the consistency of the synthetic route for a nanoformulation containing…
spectrophotometric methods by area under curve [AUC] and second order derivative methods have been developed and validated for the estimation of candesartan cilexetil in bulk and its tablet formulation ... with…
blonanserin (r2 = 0.998) and 5-30 μg/mL for asenapine (r2 = 0.996). Proposed method was validated in terms of precision, accuracy, limit of detection (LOD), limit of quantitation ... complex (ILO = 120, BLO = 120, ASE =…
simple, rapid, precise and accurate reverse-phase HPLC method was developed and validated for the simultaneous determination of emtricitabine, tenofovir and efavirenz in commercial tablets. The method has shown adequate
novel reverse phase high performance liquid chromatographic(RP-HPLC) method has been developed and validated for simultaneous estimation of Sildenafil Citrate Dapoxetine Hydrochloride in pure and marketed formulations…
ortho-phosphoric acid. The detection was carried out at wavelength 294 nm. The method was validated for system suitability, linearity, accuracy, precision, robustness and stability of sample solution with
simple gas chromatography method using flame ionization detector has been developed and validated for the quantitative determination of trace level of oxalyl chloride(quantified as diethyl oxalate) in Zolpidem tartrate…
linear in the concentration of 2.05 -25.70 μg/mL for Almotriptan malate. The method was validated by determining its accuracy, precision and system suitability. The results of the study showed
High Performance Liquid Chromatographic tandem mass spectrometric method for the estimation of Carbocisteine in human plasma has been developed and validated using Carbocisteine 13 C 3 as internal standard. Sample…
with injection volume10μL. Column temperature was maintained at 30°C .The proposed method was validated for system suitability, linearity, precision, specificity, stability, Limit of Detection and Limit of…
simple, selective, and accurate chromatographic techniques have been developed and validated for the estimation of Ivabradine hydrochloride in bulk and pharmaceutical dosage form. A high performance thin layer…
combined dosage form i.e. tablets by using distilled water as a solvent. The method was further validated by ICH guidelines. The proposed third order derivative method involves the measurement ... ambroxal hydrochloride…
present work was to develop a simple, specific, accurate and precise validated HPTLC method for quantification of Lansoprazole and Aspirin in fixed dose combination. The chromatograms were developed using…
respectively. The developed method was validated as per international conference on harmonization (ICH) guidelines, and assay of Evotaz was determined and found to be 100.82%. The stability of the drug ... range of…
first derivative synchronous spectrofluorimetric method has been developed and validated for simultaneous determination of nebivolol hydrochloride (NEB) and amlodipine besylate (AML) in combined tablet dosage forms…
validated RP – HPLC method was developed for the determination of Amoxycillin trihydrate in dosage form. The method developed produced high sensitivity, precision and accuracy. An isocratic ... Amoxycillin trihydrate…
found to be 275 nm showing highest sensitivity of both compounds. The method was validated for specificity, reproducibility, accuracy, linearity, robustness and solution stability and can be used ... marketed oral…
detection was carried out at wavelength 220 nm. The method was validated for system suitability, linearity, accuracy, precision, robustness and stability of sample solution with the linear range
ofloxacin ) were used for estimation of ornidazole. Results of analysis for methods were tested and validated for various parameters according to ICH guidelines, hence can be adopted for the routine
simple, specific, accurate and precise RP-HPLC method was developed and validated for the simultaneous estimation of Rosuvastatin Calcium and Ezetimibe in pharmaceutical formulation with forced degradation studies. The…
first order derivative method with coefficient of correlation value as 0.9997 respectively. A validation of above methods was carried out as per ICH guidelines. The precision expressed as relative standard
phenytoin sodium capsules in an Immediate Release formulations. The method has been validated. The method employs Waters UPLC system on Acquity BEH C18, 100 x 2.1mm, 1.7μm column ... about 1.4mins.The method was…
combined tablet formulation using a very new , simple, accurate and precised method called ‘Absorption correction method’ using UV spectrophotometer. Beer’s law was obeyed for Norfloxacin in the range ... were less than…
novel reverse phase liquid chromatographic method was developed and validated for simultaneous estimation of antiseptic drug, boric acid and antifungal drug, chlorphenesin in its dosage form i.e. prickly heat powder…
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.