column, a fluorescent detector (Ex. 360; Em. 470 nm), a run time of 25 minutes and an isocratic elution at 30°C. The methodology was validated in terms of selectivity
selective, linear, precise, and accurate RP-HPLCmethod was developed and validated for the estimation of Aceclofenac from bulk drug. Chromatographic separation was achieved isocratically on a Phenomenex, C8 column
selective and specific LC-tandem MS method has been developed and validated for simultaneous quantification of ticarcillin and vancomycinin solution and in presence of degradation products. Atlantis® C18 Column
column. Imipramine was used as the internal standard. The liquid-liquid extraction recovery was found 76% indicates good recovery. The present method was found to be sensitive and selective
selected dual media filters. To verify the goals of this work a pilot plant similar to the classical water treatment plant was constructed. Filtration system consisted of four glass column
selectivity for different organic reactions. The catalyst could be recycled and reused several times. The reactions occur at room temperature in presence of small amount of the catalyst. No column
selective and accurate high pressure liquid chromatography-tandem mass spectrometry (HPLC–MS/MS) method has been developed and validated for simultaneous monitoring of Aripiprazole and its active metabolite…
simple, selective, accurate isocratic high performance liquid chromatographic (HPLC) method was developed and validated for the analysis of Elvitegravir (EVG) in pure and in dosage forms. Chromatographic separation was…
alcohols; however, these reagents show some drawbacks, such as toxicity, lack of sensitivity and selectivity, low solubility, and high cost. Using fluorescent heterocyclic compounds as labels is an outgrowing field…
HPLC method was developed for selective and simultaneous determination of Guaifensen and Dextromethorphan HBr tablets 1200/60 mg. The chromatographic separation was achieved on a Acquity UPLC ... column. The mobile…
simple, rapid, selective, precise and accurate isocratic reverse phase high performance liquid Chromatography assay method has been developed for estimation of Calcium dobesilate in tablet formulations. The separation…
optimum pH was 7.1, the flow rate was 0.7 ml/min and the optimum column temperature was 45°C for the phenols separation.The separation parameters were calculated, including the chromatographic ... parameters such as the…
column temperature was 40°C. The total analysis run-time was 5 min per sample, and no interfering peaks from aqueous humor were detected. Method was found to be selective
detection was achieved for determination of ertapenem antibiotic, in forensic samples. Methanol was selected as the supported liquid membrane. The elution was done by formic acid. Chromatographic separation of drug…
preference of microhabitat variables such as (i) distance from the stream bank (ii) water column depth (iii) mesohabitat (iv) water velocity (v) substratum and (vi) subaquatic vegetal cover were quantified ... based on…
phosphate (pH3.5) in the ratio of 60:40v/v which was pumped through the column in isocratic mode at the flow rate of 1.0ml/min. The detection was carried ... method was validated for linearity, range, precision…
column Chromolith (RP-18e, 100 mm x 4.6 mm, 5 μm), a binary mobile phase; A: 0.1% formic acid in deionised water, B: 100% acetonitrile. The validation aspects were selectivity
separation of drugs in reversed-phase mode using Waters HPLC 22695 model,Inertsil ODS column(250 x 4.6 mm, 5μm particle size).The optimum mobile phase consisted of methanol: phosphate ... buffer in the ratio of 80:20…
performance of the tests for identification, purity and assay. Analytical parameters precision, accuracy, selectivity, linearity, limit of detection and limit of quantitation were studied and compared. The both methods…
simple, selective, rapid, precise, sensitive and accurate HPLC method has been developed for the estimation of nitrendipine in tablet dosage form. The method was carried out on a Phenomenox ... column (250 mm x 4.6 mm…
simple, selective, rapid, and precise reverse phase HPLC method has been developed for the simultaneous estimation of Ofloxacin and Satranidazole in pharmaceutical dosage form. A Phenomenex Luna ... column was used for…
controlled setting. Whole honey has been sent to the laboratory for compound isolation through column chromatography. Three compounds have been isolated namely compounds (1-3). The isolated compound along with ... honey…
sensitive, selective and precise high performance liquid chromatographic method has been developed and validated for the simultaneous determination of Dosulepin and Methylcobalamin in tablet dosage form. The method…
including spices. The present study aims to investigate the concentration of Ochratoxin–A in selected spices from Dharwad. A total of 20 samples belonging to 5 spices were analysed ... Ochratoxin-A content by HPLC (High…
achieved using a Phenomenex Luna ® C 18 (2) (5 μm, 250 x 4.60 mm) column and isocratic elution with a mobile phase consisting of acetonitrile, water, and formic acid ... Mass spectrometry detection using electrospray…
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.