process. The chromatographic analysis was performed on Waters-600 system using a isocratic mobile phase comprising methanol:water (80:20 % v/v) with pH of water modified to 3 using ... column maintained at 30 ± 1 °C…
coloumn is used as stationary phase. The flow rate was maintaibed at 1 ml/min and detection was performed at 233 nm using DAD detector. The retension time
achieved by saponification and solid-phase extraction (SPE) and the determination was done by using high performance liquid chromatography (HPLC) with a Diode array detector. Q10 level was determined
mobile phase at a flow rate of 1.0 ml min-1 and the detection was monitored out by photodiode array detector at 235 nm. The retention time for Rosiglitazone maleate
taken as mobile phase, at flow rate of 1.5 ml min-1. Detection was carried out at wavelength 319nm using photodiode array detector. Drotaverine was subjected to different ICH prescribed
using a mobile phase of acetonitrile, methanol and 1-Hexane sodium sulfonate. Flow rate was 1.5 ml/min. The photo diode array detector was operated at 266 nm. The method
chromatograph coupled with an electrochemical detector was employed, equipped with a gold working electrode and an Acclaim 300 analytical C18 column, with a mobile phase consisting of sodium acetate (NaOAc
using the methanol water mobile phase in the ratio of 30:70 (v/v). The active ingredient of the drug content quantify with UV detector at 359 nm. The retention
ratio 80:20 as mobile phase, at a flow rate of 1.0 mL min-1. UV detection was performed at 269 nm using DAD detector. The method was validated according
mobile phase was delivered at a flow rate of 1 ml/min and the detection was made by Ultraviolet (UV) detector at 210 nm. This method was fully validated
using a mobile phase of 55-45% of Buffer and methanol. The detection was performed by a photo diode array and UVvisible Detector. In Linearity over concentration range
efficiencies when the mobile phase is linear gradients of Methanol in an aqueous sodium acetate (50mmol/L, pH 5.40), using diode-array detector at 350nm
Zorbax C18 column. The mobile phase (gradient elution mode) consists of methanol, acetonitrile, and water (pH = 3.0); the eluents were monitored by photodiode array detector (wavelength
using a mobile phase consisting of acetonitrile- 0.1% phosphoric acid (pH 3.0) (80:20) at a flow rate 1.0 ml/min. The detector wavelength was at 268 nm with
UPLC C18 column. The mobile phase (gradient elution mode) consists of methanol, acetonitrile and water (pH=3.0); the eluents were monitored by photodiode array detector wavelength
common platform onto which diff erent THz components, e.g., source, waveguide, modulator and detector can be monolithically integrated. With the development of THz quantum cascade laser (QCL), it has been ... integrated…
oxalate and R-enantiomer of escitalopram oxalate in bulk drug and tablet using uv detector at 240 nm. The developed method was able to separate R-enantiomer of escitalopram oxalate ... bulk drug within 25 min. The…
mediated by a mobile phase under high pressure, to achieve separation based on chemical and physical properties. Modern HPLC systems are equipped with sophisticated detectors such as UVVis, fluorescence
with mobile phase comprising of phosphate buffer: acetonitrile (70:30), pH-2 at a flow rate of 1ml/min and Ultra Violet detector at 230nm. Lignan 1-phenylnaphthalene was eluted
column with a mobile phase - a mixture of 0.1 M ammonium acetate solution and acetonitrile (40 : 60); The flow rate- 1.0 mL/ min; The detector wavelength - 280 nm; The injection
column, a mobile phase of methanol(MeOH): acetonitrile(ACN): water in a proportion of 10:80:10 (v/v/v) and UV7000 Techcomp detector was used at a detection wavelength
5μm) column, mobile phase of composition 10:30:60 (v/v/v) of tetra hydro furan (THF), methanol (MeOH) and acetonitrile (ACN), UV detector were adopted for the chromatographic analysis
60F254 plate. The mobile phase used was acetonitrile: triethylamine (5:0.2 v/v). The detection of spots was carried out densitometrically using a UV detector at 279 nm in absorbance
mobile phase with flow rate of 1 mL/min and injection volume was 20 μL. Quantification was carried out with UV detector at 230 nm with a linear calibration curve