presence of both local and systemic infection with high sensitivity and specificity. Receiver-operating characteristic AUC of presepsin diagnostic utility for all types of infected complications of acute necrotizing…
respectively at 5.5 cutoff level. Diagnostic accuracy was determined as receiver operating characteristic (ROC) curve, suggesting that the area under the curve (AUC) of Doppler USG at S/D cutoff
model incorporating gender and axial-length corrected ETDRS regions; we generated a receiver operating characteristic curve with a c-statistic of 0.80. Conclusion: Our study, which to our knowledge
method. Serum PS-129 α-syn concentrations were measured by ELISA assay. Receivers Operating Characteristic (ROC) curves were applied to map the diagnostic accuracy of PD patients compared to healthy
know that for clinical purposes, reporting diagnostic added value should be considered using receiver operating characteristic (ROC) curve because all the above mentioned validity estimates can be acceptable while…
each ecological niche model was assessed using the area under curve of a receiver operating characteristic (ROC) curve. The results show that the total extent of occurrence of all selected
enteric fever patients, whereas leucopenia was not a significant finding (p=0.096). Using Receiving Operating Characteristic (ROC) curves, it was observed that patients with both
eGFR with serum level of SBP-1 (r=0.188, p=0.036) was observed. Receiving operating characteristics test shows that the area under the curve of the waist to height ratio
values along with the diagnostic accuracy of these methods were determined by receiver-operating characteristic (ROC) curves. Results: Histological liver fibrosis was evaluated by Metavir scoring (F0: 10 cases
modeled toxicity in USGRT group using the ULR model. We performed Receiver Operating Characteristics (ROC) analysis on all of the models and compared the Area under the ROC curve
test and the correlation between the numerical variables by the Spearman test. The Receiver Operating Characteristic (ROC) curve was used to evaluate the predictive capacity of the neck circumference
duration for c-TCD. Receiver operating characteristic (ROC) curve analyses and Spearman’s rho rank correlations were performed for the different time windows to calculate the areas under the curve
anti- MDA level >71.3 U/mL (cut-off value derived from receiver operating characteristic analysis). The patients with an anti-MDA value below cut- off value had a higher mortality
anti- MDA level >71.3 U/mL (cut-off value derived from receiver operating characteristic analysis). The patients with an anti-MDA value below cut- off value had a higher mortality
emergency department from June to August 2017 at Ospital Ng Makati, Philippines. Receiving operating characteristic curves were generated to determine optimal cut off scores of SOFA in predicting
Results indicated that lymphocyte sensitivity was cancer status dependant, thus an analysis of Receiver Operating Characteristic curves was undertaken on 208 individuals. The mean log Olive tail moments
compared with the control groups (0.58±0.30) (p<0.001). The area under the receiver operating characteristic (ROC) curve for NLR (0.885) was higher than CRP (0.783). ROC curve
groups. As expected, the levels of IFN-γ in SPSs returned a high receiver operating characteristic curve (AUC) value comparing healthy controls and LTBI cases
longer hospital stay was observed in patients with reduced APMT (p=0.001). A receiver operating characteristic (ROC) curve, plotted considering the SGA Ped as the gold standard, suggested APMT cutoff
between pre- and postmeasures and Cronbach's α values. Validity was measured by Receiver Operating Characteristic (ROC) curve. Expert pain physician diagnosis was considered as the gold standard for comparing
agreement, and Cohen's Kappa; and validity by sensitivity, specificity, correctly classified, and Receiver Operating Characteristic (ROC) curve. Physician diagnosis was considered as the gold standard for comparing the…
reduced in PE women compared with normotensive pregnancies. In 2nd trimester, area under Receiver-Operator Characteristic (ROC) curve was 0.662, positive and negative predictive values were
ZWOLLE, LLOYD-JONES) with additional risk factors was evaluated with the area under receiver operating characteristics (ROC) curve. RESULTS: Multivariate analysis identified following independent risk factors improving…
selection of an optimal threshold value, as a summary measure of the Receiver Operating Characteristic (ROC) curve. The aim of this paper is to make use of generalized approach
selection of an optimal threshold value, as a summary measure of the Receiver Operating Characteristic (ROC) curve. The aim of this paper is to make use of generalized approach
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.