used was (150 mm×4.6 mm, 10μm) C8 LichrosorbTM analytical column. The method was linear in the range ... checked using laboratory prepared mixtures. The proposed method was successfully applied to the analysis of OMP…
well-resolved peak for atazanavir with retention time of 5.78 min. The linear regression analysis for the calibration curves showed a good linear correlation over the concentration range
solutions in the pH range 6-9. The LC-MS analysis of MCs after MIP extraction showed an excellent linearity in the working range (R2=0.998) with high repeatability ... comparable with the detection limit of the…
cell disease treatment. We developed a liquid chromatography method with electrochemical detection for hydroxyurea analysis in plasma and aqueous solutions. Analytical goals included an analytical range from…
economic reversed phase high-performance liquid chromatography (RPHPLC) method has been established for simultaneous analysis of Metformin hydrochloride and Rosuvastatin in bulk powder and In-House Formulation on a…
spermine) and three biogenic compounds (4-aminobutyric acid, histamine and dopamine) separated completely with linear calibration range 1-10 μg/ml and limits of detection ... nitrogen flow rate was 3.0 ml/min. The…
mobile phase having pH of 5.01. The compounds were quantified by quantitative analysis in absorbance mode at 233 nm. The system gave compact spots for acetylbarlerin, barlerin and shanzhiside methyl ... with optimum…
considered several variables, and for each an individual meta-analysis was performed. Results: Meta-analysis reveals the potential utility of HRV index variables as indicators of PTSD. For high frequency ... under the…
more stiffness for the system as compared with upper locations. A number of non-linear static (pushover) analyses were performed on proper structural models of the building, considering both bare ... appraise the…
Sexual pleasure was operationalized using one measure with 8 items (reliability analysis was good α=0.76). Participants were asked to recall their sexual experiences and their sexual behaviors over ... having sex with…
performed using Deming Regression analysis and revealed good agreement between CE and all methods. Although the HPLC method showed a linear relation with CE, it differed significantly from the comparative
validated according to ICH guidelines. The reduced run time and low cost of analysis are additional merits of the method. This method showed the best resolution by using pre-packed ... average operating pressure of 130…
laser dynamics issue, from which results that go beyond the well-known linear stability analysis are extracted. The method of investigation is rooted in weak and strong- harmonic Fourier-expansions
impact of these variants on obesity, glucose homeostasis and lipid traits using multiple linear regression analysis. Results: Our findings could not confirm the association of PPARγ polymorphism with T2DM
ratios (PTR) were determined by AutoCAD 2010. Data were subjected to correlation and regression analysis which indicated that 2nd premolar (PM2) was the most closely correlated with ... among tooth combinations, the…
This difference lost significance after adjustment for confounders. In a linear regression analysis resistin levels were not associated with body mass index, obesity, homeostasis model assessment- index, systolic and…
pharmaceutical dosage forms. Analysis was performed using methanol: aceonitrile (50:50) as diluents. UV detection was performed at 254 nm. The calibration plot was linear over a concentration range
Indian adolescents from the follow-up survey of the Hyderabad Nutrition trial. Methods: Analysis was done on data collected from 1162 adolescent participants of the Hyderabad Nutrition trial follow ... waist…
diameters were 11.68 ± 0.52 mm and 11.82 ± 0.74 mm, respectively. Linear regression analysis found a statistically significant correlation (p=0.004) between them, however, there was a large degree of scatter
living tumor cells. Validation of the ELISA showed a high assay precision and linearity in a concentration range of 0.36-17.4 ng/ml. A comparison of the recovery of spiked ... higher recovery was found with the lipHsp70…
analysed descriptively to enable trends in MI queries to be identified. Multiple linear regression analysis was used to predict time taken to complete enquiries.Results: 1605 MI enquiries were analysed
lower water activity and moisture content in atomized umbu. However, the effects of the linear, quadratic, and interaction factors were not statistically significant over hygroscopicity and process yield ... higher…
TOFMS method was validated according to the SANCO guidance in terms of linearity, selectivity, reproducibility and recovery. Regarding the results, recovery rates ranged between 70-120% with relative standard deviations…
separated from the total effect. Moreover, the derived mediation analysis can be performed with general predictive models. For linear predictive models with continuous mediators, we show that the proposed method
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.