Development and validation of sensitive and selective method for enantioseparation and quantitation of synthetic cathinones âÂ?Â?bath saltsâÂ? has been done by using GC-MS with chemical ionization source ... which…
analyte was extracted from a 500µl plasma sampler and separated on a RESTEK C18 column (5 µm, 250 x 4.6 mm). Propranolol was used as an internal standard. The analytes ... with a UV Photodiode Array Detector (PAD) at…
generate high-pressure flow of the mobile phase, an injector for sample introduction, a column for separation, a detector to monitor the eluting compounds, and a data analysis system. Various ... such as UV-Vis…
pharmacological activity is attributed to its R enantiomer. A single, simple and selective method for the estimation of R enantiomer of BCT in human plasma was validated using external standard ... method. The drug was…
simple, rapid, selective, precise and economical RP-HPLC method has been developed and validated for the quantitative estimation of Cefixime and Ofloxacin in pharmaceutical preparation. Chromatographic separation was…
tablet formulation. Chromatography was performed on a Hypersil C18 (4.6mmx250mm, 5m) column from inisocratic mode with mobile phase containing acetonitrile: 0.05 M KH2PO4 ... rate was 1.0 ml/min and the eluent was…
phase. The stationary phase used was (150 mm×4.6 mm, 10μm) C8 LichrosorbTM analytical column. The method was linear in the range ... respectively. The selectivity of the proposed method was checked using laboratory…
haloperidol, facilitating large number of sample analysis within short time frame. Objective: A selective and sensitive reverse phase high-performance liquid chromatographic assay has been developed for monitoring of…
action in humans. A validated HPLC method was developed for the study of the selected drug related substances. Good chromatographic separation was achieved for all the substances owing to their ... thereby resulting in…
method has proved to be a powerful research tool due to its sensitivity, high selectivity, and high throughput efficiency. Determination of Losartan in human plasma method was developed and validated.Losartan…
contaminated confined area, and (ii) São Jacinto (SJ) closer to the lagoon inlet and selected as reference site. Winter and summer conditions were considered. Eye wall was analysed for total ... than SJ in winter and…
present study aims at identifying the antimicrobial potency of the leaf fractions against selected wound pathogens covering the regular, nosocomial and burn wound pathogens, viz., Escherichia coli, Staphylococcus…
water using METROSEP C 2 250 (Metrohm, 250mm x 4.0mm, 7mm particle size) column at ambient temperature. The retention time of ethanolamine was about 10 min and the total ... optimized method was validated to prove its…
range of chiral enantioselectivity. Herein, we report novel homochiral pillared MOFs (1, 2) with excellent selectivity for HPLC enantiomeric separation of various racemates such as sulfoxides, sec-alcohols and…
Agilent 7700 with FID (DB-624, 30 m × 0.53 mm, 3 μ) capillary column, nitrogen as carrier gas with a flow rate of 2.5 ml mn-1. The critical experimental ... oven temperature, zero air, make up flow; injection volume…
Asimple, selective, linear, precise, and accurate RP-HPLCmethod was developed and validated for the simultaneous estimation of Clopidogrel Bi Sulphate and Aspirin from bulk drug. Chromatographic separation was achieved…
selective, specific and sensitive stability-indicating high-performance liquid chromatographic method was developed and validated for the determination of Tamsulosin in in pharmaceutical dosage forms. Celecoxib was used…
with chitosan, supporting preclinical pharmacokinetic studies for toxoplasmosis treatment. The method used a C18 column at 30°, mobile phase (triethylamine, acetonitrile, water; 1:20:79, pH 5.9), flow rate ... detection…
simple, rapid, selective, precise and accurate isocratic reverse phase high performance liquid Chromatography assay method has been developed for simultaneous estimation of Metformin HCl and Sitagliptin in tablet…
separation was achieved on a Kromosil -ODS C18 (250 X 4.6 mm; 5 μ) column in an Isocratic Mode. The mobile phase composed of Water [HPLC Grade ... Methanol (55 %). The flow rate was monitored at 1.0 mL/min. The…
diagrams will be discussed. Previous syntheses are improved (100%, no catalysts, no moisture, high selectivity or mostly specificity, better use of reagents (NaHCO3 instead of NaOH ... NaBH4 instead of only one, etc.)…
diagrams will be discussed. Previous syntheses are improved (100%, no catalysts, no moisture, high selectivity or mostly specificity, better use of reagents (NaHCO3 instead of NaOH ... NaBH4 instead of only one, etc.)…
getting good analysis data. We used immune affinity clean up and enrichment self-packed column to isolate hCG in urine. The isolated hormone was then subjected to reduction, alkylation ... tryptic peptide that is unique…
sensitive, selective and precise high performance liquid chromatographic method has been developed and validated for the simultaneous determination of Dosulepin and Methylcobalamin both as a bulk drug and in formulation…
sensitive, selective and precise high performance liquid chromatographic method has been developed and validated for the simultaneous determination of Epalrestat and Methylcobalamin both as a bulk drug and in…
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.