mobile phase was 1.0 mL/min and the total elution time, including the column equilibration was approximately 60.01minutes.The retention times of Bendamustine Hydrochloride and its impurities
impurities. The method has been validated for determination of related substance in Atenolol. Analytical Column: A stainless steel column 150 mm long, 4.6 mm internal diameter filled with octadecylsilane chemically
Isocratic RP-HPLC method was developed on Phenomenex Gemini C18 250´ 4.6mm, 5μm column using mobile phase as 0.02M ammonium acetate buffer pH 4.5 - Acetonitrile
Citicoline monosodium (API) and their degradation products. Chromatographic separation was accomplished using C18 column with mobile phase consisting of: Tbahs Buffer: Methanol (95:05): Methanol (95:05, v/v), flow
pharmaceutical formulation. Chromatographic separation was achieved on Hypersil BDS C18 250 × 4.6mm, 5μ column as stationary phase while mobile phase A was buffer, (Buffer=Water : Glacial acetic acid ... proved to be…
Budesonide in pressurised metered dose inhaler. The separation was achieved by octadecyl silica gel column (C18) and buffer of sodium dihydrogen phosphate and decane sulphonic acid in combination with acetonitrile
Sitagliptin in bulk as well as in pharmaceutical dosage form by using Symmetry C18 column (4.6 x 150mm, 3.5mm, Make: XTerra) in isocratic mode. The mobile phase was prepared
HPLC) method has been developed of ibuprofen in tablet dosage forms using C18 column (Hypersil BDS, 150 x 4.6 mm, 5 µm) in isocra tic mode. The mobile phase contains
methods use Phenomenox Luna (C‐18, 250 x 4.6 mm, 5 μm) column and gradient elution for both the methods. The aqueous mobile phase contained 0.02 M phosphate buffer adjusted
used in the method. Chromatographic separation was achieved on Discovery C18 column over a run time of 2.5 minutes. The molecular ion Q1 & product ion Q3 transitions were found
formulations like tablets and nanoparticles. The chromatographic system consist of a steel plated C18 column, an isocratic mobile phase composed of phosphate buffer pH 3.0, acetonitrile and water
used as the internal standard. Chromatographic separation was achieved on a Vydac C18 column (4.6×50 mm, 3 μm particle size) and the detection was made
evaluation of the studied drug. The chromatographic assay involved the use of a C8 Column (250 mm×4.6 mm i.d., 5 μm) with a simple mobile phase composed of acetonitrile
Eclipse Plus Zorbax C18 Agilent, 150 mm×4.6 mm i.d., 5 μm particle size column. The analyte was resolved by using a mobile phase 5% acetic acid aqueous solution
technique for anthocyanins was developed by integrating aqueous two-phase extraction and macroporous resin column chromatography. This new technology might be a suitable for other bioactive natural products on industrial
technology company and used as the feedstock for the SF-SMB. Using single column chromatography, the operating conditions for a series of experiments conducted with 18 wt% ethanol were examined
method symmetry C18 5 μm is utilized as the stationary phase in the HPLC column, (250×0.4 mm) at 40°C using acetonitrile- buffer 6 (29-71%) mixture as mobile
enalapril, captopril and fosinopril were eluted from a Purospher STAR RP-and Hypersil ODS column in 1.8, 2.9, 3.2 and 5.4 min respectively. Good linear relationships were observed
HCTZ) in combined dosage forms. The method was developed using Kromasil eternity C-18 column (50 mm×2.1 mm, 3.5 μm) with isocratic elution. Triethylamine buffer
with an phenomenex luna 5 μ CN 100R, 250×4.60 mm 5 micron size column, ambient temperature with a low pressure gradient mode with mobile phase containing acetonitril
using gradient elution through prepacked Nuclosil, C18 (250×4.6 mm, 10 μm) column. UV detection was performed at 250 nm. Method was validated following the ICH guidelines. Calibration curve