A rapid stability indicating LC method for stavudine using RR-LC
stationary phase with simple mobile phase combination delivered in a isocratic mode and quantification was carried out using ultraviolet detection at 265 nm at a flow rate
Articles, journals and conferences in one search. An exact title, DOI or ISSN is listed first.
In the search box: "exact phrase" · -leave out · OR · prefix* · title: author: journal:
stationary phase with simple mobile phase combination delivered in a isocratic mode and quantification was carried out using ultraviolet detection at 265 nm at a flow rate
using spiked levels of impurities, precision (repeatability and reproducibility), limit of detection, limit of quantification and ruggedness. Overall, the proposed method was found to be highly sensitive, suitable and…
sampleswas developed using liquid liquid extraction (LLE) involving ethyl acetate-hexanemixture. The limit of quantification was 100 ng/ml and linearitywas observed for calibration curves between
indicating, reversed phase high performance liquid chromatographic method (LC) has been developed for the quantification of rosuvastatin and its related substances and of degradation products generated by decomposition…
ionization source. Signal intensity was high using ESI- source provided for the quantification of samples. Chromatographic separation was performed on phenomenax C- 18 column (250ï‚´4.60mm5microns).Mobile phase
enantiomer in the developedmethod. The limit of detection (LOD) and limit of quantification (LOQ) of the R-enantiomerwas 0.15 and 0.5 µg mL-1, respectively, for 10 µL injection volume
stationary phase with simplemobile phase combination delivered in a isocratic mode and quantification was carried out using ultraviolet detection at 210 nmat a flowrate of 0.5mLmin
simple highly sensitive spectrophotometric method was developed for the quantification of Eflornithine hydrochloride (2-difluoromethyl-DL-ornithine; DFMO). U.V. Spectrophotometric estimation of Eflornithine…
molecule is a hydrochloride salt, the sample preparation was critical for the quantification of known and unknown impurities. Successful separation of ISB from the synthetic impurities achieved
Themethodwas suitably validated with respect to linearity, limit of detection and quantification, accuracy, precision, selectivity, robustness and ruggedness. The linear calibration range
limit of detection of felodipine was 25 ng/ml and limit of quantification was 50 ng/ml. Excellent precision was evident with a coefficient of variance less than
wasmonitored by UV detection at 210 nm. This method allowed for the detection and quantification of R-BOC amine of levels at 0.15 and 0.5 µg mL-1 respectively. Themethod
ionization source. Signal intensity was high using ESI+ source provided for the quantification of samples. Chromatographic separation was performed on phenomenaxC-18 column (250x4.60mm5microns).Mobile phase…
radiation force impulse imaging. Conclusion The “XXXX” values always measured at Virtual TouchTM tissue quantification allow the diagnosis of a pancreatic cystic lesion with simple fluid content suggesting the diagnosis
plasma using imipramine as the internal standar d (IS). The limit of quantification was 0.05 ng/mL and the method was linear in the range
novel antispasmodic agent. A simple, selective and precise RPHPLC method was developed for quantification of Drotaverine hydrochloride in pharmaceutical formulations. The sample was analyzed on reverse phase C18 column
fruit were evaluated from months 10 to 12. Significant linear regressions between the quantification of the leaf symptoms and the morpho-agronomic characteristics related to productivity were detected
accuracy was greater than 98%. The limit of quantification of the drug was found to be 20.5 ng/spot and the limit of detection of the drug was found
limit of quantification (LOQ) was found to be 3.415 x 10-3 5g/mL, 1.273 x 10-2 5g/mL in formulation and biological fluids, respectively. The different experimental parameters
enzyme digestion and the MTHFR A1298C polymorphism by allele-specific polymerase chain reaction. Hcy quantification was carried out by liquid chromatography-tandem mass spectrometry. The median number of polymorphic…
precise, accurate and reproducible High performance thin layer chromatographic method has been established for quantification of active compound in marketed ayurvedic formulations containing Asparagus racemosus…
present paper deals with development and standardization of HPTLC method used for quantification of Solasodine and Diosgenin in Solanum xanthocarpum. Solanum xanthocarpum Schrad. and Wendl. (Kantakari) Solanaceae is…
association ofmetallographic quantifications,micro-analysismeasurements and calculated results with iterations about the carbon content, allowed to assess the loss of all the elements during casting and to specify
range of 48-384mcg/ml. Limits of quantification was found to be 20 and 4ng/ml for CT andAM respectively
present study, the methodologies for extraction, cleanup, detection and quantification of endosulfan ï¡, endosulfan ï¢, endosulfan sulfate and chlorpyrifos residues in buffalo meat were standardized. For the…
For authors and organisers
Find the right journal for your paper and submit your manuscript.