quantification was carried out using ProntoSIL C18-EPS 4.6X150mm, 3μm enhanced polar selectivity column and mobile phase comprised of potassium dihydrogen phosphate buffer pH adjusted to 3.2 ± 0.5 with
form is developed and validated. The chromatographic analysis was performed on a kromasil C18 column (150×4.6 mm, 3.5 μm) in isocratic mode, the mobile phase consisted of acetonitrile
determination of esomeprazole and domperidone from pharmaceutical dosage forms. The method uses ODS C18 column and isocratic elution. The mobile phase composed of methanol: phosphate buffer
separation was carried out on a BEH symmetry C18 (50×4.6mm, 1.7 μm) column with a mixture of methanol: phosphate buffer pH 3.0 adjusted with o-phosphoric acid
mobile phase compatible to LC-MS analysis. The proposed method utilizes a Phenomenex C18 column (150 mm x 4.6 mm, 5.0 μ particle size), at ambient temperature, optimum mobile phase
proposed RP-HPLC method utilizes a Inertsil ODS (250 x 4.6 mm, 5m) column, at ambient temperature, optimum mobile phase consisted of 0.02%v/v formic acid and methanol
method. The individual monosaccharides were identified by GLC, TLC, paper chromatography and separated by column chromatography. It consumed 1.30 moles of iodine by iodometrically. Its IR spectral data (KBr) indicated
developed for the estimation of Dapiprazole in bulk form. A Thermo hypersil C-18 column (250 mm×4.6 mm 5μm) with mobile phase consisting of mixture of methanol: acetonitrile
liquid-liquid trichloromethane extractions. Samples were analyzed with a reversed phase liquid chromatographic column interfaced to a triple quadrupole mass spectrometer (LC/MS/MS) operating in the positive ion multiple
carries information on human health status. Ion mobility spectrometers combined with a multi-capillary column (MCC/IMS) is a well-known technology for detecting volatile organic compounds (VOCs) within human ... carries…
assay of Prasugrel in bulk . The Chromatography was performed on Kromasil C18 column . The eluted compounds were monitored by UV detecti on at 257nm using mobile phase methanol-potassium dihy
hA20 protein expression. We purified protein from the yeast fermentation supernatant using a nickel column. Human umbilical vein endothelial cells (HUVECs) were cultured in high glucose medium (30 mM glucose
Methods: The separation was based on the use of a Kromasil C18 analytical column (150 × 4.6 mm, i.d., 5 μm). The mobile phase consisted of a mixture of 70 volumes
determination of repaglinide. RP-HPLC analysis was carried out using Agilent TC-C18 (2) column and mobile phase composed of methanol and water (80:20 v/v, pH adjusted
neopterin turns to oxidize form. Excitation and emission wavelengths were 275 and 345 nm. Column was C18, 5μ, 4.6x150 mm, RP. Injection volume was 10 mL. Flow rate
carried out isocratically at 25°C ± 0.5°C on an Prontosil C-18 column (4.6 x 250mm, 5μ particle size) with a mobile phase composed of acetonitrile-methanol-phosphate buffer
commercial pharmaceutical products. The Impurities were well separated on a Waters Spherisorb ODS-1 column ( 250mm X 4.6mm, 5µm) by the gradient program using 0.05 M Phosphate buffer
method in both the techniques. HPLC method was developed using HiQ sil C8 HS column, with mobile phase containing mixture of Acetonitrile: Sodium acetate buffer(0.04M) containing n-hexane
purification of the compounds by passing the plant extract through sephadex LH-20 column. pCoumaric acid, rutin, apigenin, quercetin, chlorogenic acid and syringic acid were found and isolated
Forms. Chromatographic separation was achieved on a Symmetry C8 (250×4.6 mm), 5.0 µm column with a 60:25:15mixture of 0.02M potassium dihydrogen phosphate w/v, acetonitrile
using acetonitrile as precipitating agent. The samples were analyzed on HiQ sil C18 HS column with the mobile phase containing mixture of methanol: phosphate buffer 0.01M (pH 3.0, adjusted
acid hydrolysis of polysaccharide with sulphuric acid and obtained hydrolysed compound was characterized by column and paper chromatographic analysis was found D-galactose and D-mannose in 1 : 4 molar
plasma was carried out by precipitation method. Analysis was performed using Kromasil C18 column (250 �?� 4.6 mm; 5μ) with mobile phase consisting of acetonitrile and 0.02 M sodium dihydrogen phosphate