different datasets in the study area has enabled the sub-division of the stratigraphic column of the wells into sequences, systems tracts and sedimentary cycles. These sequences may have potential
degradation products were achieved on reverse phase LiChoCART with Purospher (RP-18e) column. The mobile phase was composed of methanol/water (75:25, v/v). The detection wavelength
Methods: The RP-HPLC system with Luna C18 (2) 100 Å, 250 × 4.6 mm column was used in this study. The analysis was performed using the mobile phase: 0.1% acetic ... acid in acetonitrile and 0.1% acetic acid in water…
quantification is carried out using YMC‑Pack CN (250 × 4.6 mm, 5.0 μm) column and the mobile phase comprises of 0.05% Trifluoro acetic acid (TFA) and Acetonitrile
Vitex negundo Linn leaves. Analysis was carried out using Waters’ symmetry C-18 column with acetonitrile: methanol (80:20) as isocratic elution mode with UV detection
compounds tested. Based on the phytochemical screening tests the chloroform extract was subjected to column chromatography and yielded two compounds namely, betulinic acid (1) and, benzoic acid (2). The structures
carried out on a Hibar C18 (25 cm x 4.6 mm i.d., 5 μ) column with a mobile phase consisting of acetonitrile: potassium dihydrogenortho phosphate (adjusted to pH 3 using
routine quality control analysis work. Symmetrical peaks were obtained through experimental trials. Two columns were used for performance investigations, including Kromasil C18 (5 micron 4.6 × 250mm) and Qualisil…
itopride hydrochloride in tablet dosage form. The quantification was carried out using C 8 column (250 mm × 4.6 mm), 5-μm particle size SS column. The mobile phase comprised
reverse phase chromatography on Shimadzu HPLC, 10-At detector with hypersil ODS C18 Column 250 X 4.6 mm (particle size of 5μ) and constant flow pump. Rheodyne injector with 20μl
biological fluids. Two chromatographic techniques, a nonchiral derivatization with chiral (chirasil-L-val column) separation in a GC-MS system and a chiral derivatization with Marfey’s reagent
validated. Separation of telmisartan from plasma components was achieved on a Chromolith RP18e column (100 x 4.6 mm 5 μ). Losartan was used as an internal standard. A mobile phase
Internal Standard (IS). The chromatographic conditions comprised of a reversed-phase Lichrocart / Lichrosphere C18 column (250 x 4.0 mm packed with 5 μ) with mobile phase consisting of a mixture
water containing 40 x 105 CFU bacterial colonies was passed down a silver/charcoal column and the filtrate incubated overnight at room temperature in McConkey agar plates compared with
then deproteinized by trichloroacetic acid. The analytes separated by HPLC on pinnacle II C18 column (water). Nicotinamide is used as internal standard. The mobile phase is 0.05 M ammonium acetate
form and tablet dosage form. The method was carried out using Hypersil ODS 3V column (250 mm × 4.5 mm i.d., 5 μm particle size) with mobile phase comprised of Buffer
their combined tablet dosage form. The method was carried out on a Hiber C18 column (250 mm×4.6mm, i.d.5 μm) with a mobile phase consisting of acetonitrile:methanol:water
evaluation within 6 weeks. Each laboratory was provided with reference standard, internal standard columns and precolumns. Spiked plasma samples were shipped under dry ice from Germany to “Gesellschaft fuer…
sensitivity profile, as well as retention time of the antibacterial substances on a C18 column. These results suggest that a nisin-like substance is produced by the CWBI-B1410 strain
flower six main groups of bundles were described, e.g., recurrent bundles in central column of ovary were observed. It was ascertained that ovules supply by the complex of ventral
nearly all processes in liquids are ultrafast. An ultrafast spectroscopic method using monolithic column high-performance liquid chromatography was evaluated for the simultaneous determination of a drug discovery…
bulk and pharmaceutical dosage forms. Chromatography was performed on a supelco RP C-18 column (250 mm × 4.6 mm) with 5 μm particle size. The mobile phase consists
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.