cartridges, (Waters Corporation, Mumbai, India). The reconstituted samples were chromatographed on a C18 column by using an 85:15, v/v mixture of methanol and 0.1% v/v formic acid
estimated to be greater than 5000 mg/kg B.W. The extract and its column chromatographic fraction F3 significantly (p < 0.05) and dose-dependently reduced frequency of stooling in castor
best results were obtained using acidified water (pH 2) and a solid phase extraction column purification step. Qualitative analysis was performed by HPLC-DAD/MS and, in all samples; nine
chromatographic separation was performed on Waters Acquity UPLC system and BEH Shield RP18 column using gradient elution of mobile phase A and B. 0.01 M phosphate buffer adjusted
resulted solution were injected into the chromatograph. Peaks were eluted from a Novapak-C8 column using a mobile phase consisting of acetic acid: triethylamine: acetonitrile: water
separation of the drugs was performed by using a Phenomenex-ODS-3 (C-18) column (250 × 4.60 mm, 5 μm) with a mobile phase consisting of methanol:acetonitrile
mass spectrometer, via a transfer line. Chromatographic separation was performed on HP5-MS capillary column (30 m x 0.25 mm x 0.25 μm), followed by mass spectrometric detection
Quantitation was done by separation on an HP 5-MS capillary column (30 m × 0.25 mm × 0.25 μm), followed by mass spectrometric detection in the selected ion monitoring (SIM) mode
HPLC method based on separation of imipramine and chlordiazepoxide on a reversed phase C18 column, using a mobile phase of methanol at temperature 27+2 °C and UV detection
found to occur under sun light and thermal, were successfully resolved on a C18 column (5S, ODS 25 cm × 4.6 mm, 5μm), utilizing mobile phase of 0.025 M orthophospharic acid
rivastigmine bulk dosages form. The separation was conducted by using C-18 RP-HPLC column. Which was maintained at ambient temperature. The mobile phase consist Potassium dihydrogen phosphate buffer
carried out by using Inertsil, ODS-3V C18 (250 X 4.6 mm) 5μm column. Mobile phase comprising of water: acetonitrile (75:25 v/v) was used to achieve good resolution ... proposed method is found to be sensitive, precise…
carried out at 271 nm. The separation was achieved using C18 reverse-phase column (250 X 4.6 mm I.D., particle size 5μm). The method was linear over the concentration range
Separation was carried out on Jasco HPLC system equipped with HiQ sil C18 HS column (250 × 4.6 mm i.d.) and PDA detector using Methanol: Sodium acetate buffer
been validated for determination of related substance in aripiperazole using C8 ODS (150X4.6mm) column by keeping the flow rate of 1ml/min and having sensitivity of 0.5.The elution is carried
postmenopausal women. The method was carried out on a C-18 reverse phase column (LichroCART, 150 X 4mm, 5μm; Merck) using 2 mM Heptafluorobutyric acid: Acetonitrile
Schiff base ligand, N,N’- Bis(salicylidene)1,3-propylenediamine is reported on a column of silica. Metal chelates chelates are well resolved with good peak shape and efficiencies when
form. Separation is achieved with an Ace5- C18,( 250 X 4.6)mm,5m analytical column using buffer-acetonitrile (65:35, v/v) of pH 5.5, adjusted with acetic acid ... double distilled water. The instrumental setting is flow…
enantiomers of topotecan were resolved on a Chiralpak ADH(immobilized amylose based stationary phase) column using a mobile phase consisting of Methanol:acetonitrile:diethyl amine
chromatographic system prominence consisting of quaternary solvent delivery pump, a degasser, an injector, column oven and photodiode array detector, LC 20AT series. C18 (4.6*250) mm, 5 micron column
estimation of Lorazepam in tablet dosage form. An Inertsil ODS Ultrasphere 5 μm column having 4.6 mm x 15cm internal diameter in isocratic mode with mobile phase containing Methanol : Water
contain C. longa. The separation was achieved within 3.5 minutes using a C-18 column, a water/acetonitrile mobile phase, containing formic acid at a temperature