bulk drug and pharmaceutical formulations. Optimum separation was achieved in 3 minutes using C18 column (100×4.6) mm×5μ Kromasil ODS and mobile phase was (methanol: phosphate buffer
tablet dosage form. In this method Phenomenax Luna C18, 250 x 4.6 mm, 5mm column with mobile phase consisting of acetonitrile and 0.02 M phosphate buffer in the ratio
esomeprazole in bulk and capsules dosage forms. The separation was achieved on C18 analytical column (250 mm × 4.6 mm i.d., 5.0 μm) using acetonitrile and phosphate buffer
leaves of Helicanthus elasticus Linn. (Loranthaceae). The cuticular extract was subjected to column chromatography and isolated compound characterized by UV, IR, HPTLC and MS studies and compare with standards. From
form. Separation was achieved under optimized chromatographic condition on a Zorbax-SB-18 ;(ODS) column (150 X 4.6 mm i.d., particle size 3.5μ).The mobile phase consisted of Pentane
triplinerve using GC – MS. Methods: Ten grams of the powdered sample was subjected to column chromatography over silica gel (100- 200 mesh) and eluted with n-hexane, chloroform, ethanol ... analysis was carried out on a…
centrifuged, and then clear solution was injected onto Zorbax C18 column. The mobile phase (gradient elution mode) consists of methanol, acetonitrile, and water (pH = 3.0); the eluents were monitored
achieved on a Lichrosphere Lichrocart RP 18 (250 mm, 4 mm, 5 μm, Merck) column, with the mobile phase consisting of a mixture of 0.5% phosphoric acid in triple distilled ... acetonitrile (75:25). The flow rate was kept…
rocuronium in human plasma. The plasma samples were separated on an Agilent SB-C18 column (150×2.1 mm, 3.5 μm) with a mobile phase consisted of 20 mM ammonium acetate
within 24hours before extraction and were screened for Aflatoxin M1(AFM1) using immunoaffinity column and High performance Liquid Chromatography with fluorescence detection. Aflatoxin M1 was detected in 17 samples
dental & skeletal flurosis such as mottling of teeth, deformation of ligaments, bending of spinal column and ageing problem. Overall all water quality was found unsatisfactory for drinking purpose without
been extensively employed as prime load-bearing members, such as wall studs, floor joints, columns and beams, in low to medium-rise buildings such as offices, hotels, flat blocks
contamination was carried out on Gas Chromatograph-Electron Capture and TID Detector with capillary columns. Eggplant was found contaminated with monocrotophos, phorat, quinalphos, pendamethalin, carbaryl, p,p’ DDT…
reaction was become slowly without catalyst. Production of esters in a reactive distillation column is a promising alternative to the conventional sequential process. In the present work, the modeling ... simulation of…
Chromatographic separation of analyte and internal standard were carried out using a reverse phase column, Hypersil, Gold, 4.6 X 50 mm, 5 μ at a flow rate
obtained. A log-log analysis of the hypoxanthine calibration curve was linear. Column efficiency determined from toluene and biphenyl in 90 : 10 % (v/v) methanol/water mixtures at a flow
carried out using an ODS packing L1, 250 x 4.6 mm, 5 µ,column at 27°C with a mobile phase acetonitrile : 0.05 M monobasic ammonium phosphate buffer : tetrahydrofuran
pharmaceutical formulations. This method is based on using a Luna 5 μ C18 column, the size of coloum 5 micron, 250 x 4.60 mm from phenomenex. The mobile phase
pharmaceutical formulations. This method is based on using a Luna 5μ C18 column and the size of coloum is 5 micron, 250 x 4.60 mm from phenomenex. Mobile phase
chromatographic method was developed for simultaneous determination of lisinopril and amlodipine in tablets. A column having 150 × 4.6 mm i.d. in isocratic mode with mobile phase containing acetonitrile: phosphate buffer
pharmaceutical formulation. Chromatography was performed by HPLC 2695 Waters Separation Module with Develosil C8 column 4.6×250 mm, with 5 µ particle size and the column maintained at ambient temperature
shade dried fruit coat husk powder of Juglans nigra (Wall nut) was subjected to column chromatographic separation which yielded 7 fractions. The fractions were then subjected for different spectral
Methods: The method was developed by using ACE-C18 (250 × 4.6 mm) 5-µm column with mobile phase containing a mixture of solvent A (water) and solvent B (methanol ... respectively. The flow rate was 0.8 mL/min with…
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.