achieved by utilizing a Water Symmetry C18 (150 mm × 4.6 mm) 5 µm column particle size and a gradient elution method. The mobile phase A contains a mixture ... respectively. The flow rate of the mobile phase was 0.8…
acetate using Heidolph Vortex. The chromatographic separation was performed by using HyPURITY ADVANCETM C18 Column (3 × 50 mm) with a mobile phase of 80% methanol and 20% 2 mM ammonium
internal standard. Separation of the analytes was achieved on a porous graphitic carbon column (100 mm length × 2.1 mm i.d., 5 μm particle size) by isocratic elution with 250 mmol
Methods: The separation was performed on an inertsil C8 (5 µm, 4.6 × 250 mm) column in isocratic mode with the mobile phase consisting a mixture of methanol and sodium phosphate
impurities and degradation product formed under stress conditions was achieved on a Symmetry C18 column using a mixture of water and Acetonitrile (64:34, v/v) as mobile phase
bulk. In this method a C18, 25 cm 5μ 4.6 mm ID (Oyster) column with mobile phase consisting of Sodium acetate buffer pH 3.0: Acetonitrile (70:30) was used
commercial extract of Luo Han Go (Siraitia grosvenorii) on a C-18 column using a Biotage Flash Chromatography system. The structures of the isolated compounds were characterized as kaempferol
drug and its degradation products was successfully achieved on a Hypersil BDS C18 column using mobile phase consisted of citrate buffer (adjusted to 2.5 pH by citric acid):Acetonitrile
Epichlorohydrin (ECH) in Pharmaceutical drug substances. This method utilized a Alltech AT-WAX GC column stationary phase consists of 100% polyethylene glycol, helium as carrier gas with flame ionization detection…
atenolol, amiloride hydrochloride and hydrochlorothiazide. Chromatographic separation was carried out on a C18 column with a mobile phase consisting of 25 mM sodium acetate anhydrous: acetonitrile: triethylamine
HPLC separation of BC from its degradation product using an Agilent Zorbax ODS (C18) column with a mobile phase consisting of methanol: acetonitrile: water ... HPLC separation of NaCr from its degradation product using…
products. Separation was achieved on a Kromasil C8 (250mm×4.6mm i.d; 5 μm) column at a detection wavelength of 265nm, using a mobile phase consisting of acetonitrile
best results were obtained using acidified water (pH 2) and a solid phase extraction column purification step. Qualitative analysis was performed by HPLC-DAD/MS and, in all samples; nine
crude extract. The separation system consisted of a Phenomenex C18 reversed-phase column, using phosphate buffer / acetonitrile (80:20) and acetonitrile / water / methanol (90:5:5) as mobile phase
human urine samples, the separation was accomplished on a C18 5 µm ODS hypersil column (250 mm × 4.6 mm) using a methanol acetonitrile - 0.02 M di - potassium hydrogen orthophosphate
added to each of the transferred supernatant. The mixtures were applied to spin columns followed by a centrifugation step to remove buffers and other residues. Washing step was carried ... twice by applying 70% ethanol…
formic acid: methanol at flow rate of 0.4 mL/min on Symmetry Shield RP18 column with a total run time of 3.0 min. TheMS/MS ion transitions monitored were
validated. The chromatographic conditions comprised of an isocratic reversed- phase separation on Discovery C18 column. Elution was carried out using acetonitrile: phosphate buffer
perindopril and amlodipine. Separation of the drugs was achieved on a reverse phase C18 column using mobile phase consisting of phosphate buffer and acetonitrile in the ratio
recovery. The chromatographic separation was performed on Thermo Scientific BDS HYPERSIL Phenyl reversed-phase column (250mm×4.6mm, 5μm). The mobile phase was consisted of 0.1% ortho-phosphoric acid: Methanol
simultaneous determination of Paracetamol (PC) and Mefenamic acid (MA) in tablets. The column used was Inertsil ODS 3V C18, 250 x 4.6mm, i.d. 5μm and a mobile phase composed
adjusted to 3 with glacial acetic acid, was run through a Column C-18, (EC 150/4.6 NUCLEOSIL 100-5), reverse phase analytical column. The experiment was carried
respectively. The analysis was conducted on Agilent zobrax ODS (C18) column, 5 mm particle size (4.6 x 250 mm), using ondansetrone hydrochloride as an internal standard and a mobile phase
HPLC separation was carried out by reverse phase chromatography on inertsil ODS-3V column (5μm; 250x4.6mm) with a mobile phase composed of 0.02M potassium dihydrogen orthophosphate, 0.02M dipotassium
azido-3-methylbutanoic acid, R-enantiomer was achieved using a Chiralpak IA column using a mobile phase containing n-hexane, ethanol, isopropyl alcohol and tri-fluoro acetic acid