method was validated using an Acquity UPLC™ HSS T3 (100 × 2.1 mm2) 1.8 μm column with a isocratic mobile phase containing a mixture of 0.01 M potassium dihydrogen orthophosphate ... flow rate of the mobile phase was 0.4…
porosity 300 Å, particle size 5 μm) with a guard column (reversedphase C18 column of 4.6 mm ID × 12.5 mm L, porosity 300 Å, particle size 5 μm) using ... factors; age effect of the mobile phase and test sample and with…
HPLC separation was carried out by reverse phase chromatography on an inertsil ODS-3V column (5 μm; 250 × 4.6mm2) with a mobile phase composed of 0.02 M potassium dihydrogen
Methods: Separation and detection of trigonelline was carried out on a Cosmosil CN-MS column eluted with methanol:distilled water [95:5, v/v; pH 3.5 using hydrochloric acid]. Detection
synthetic mixture form. Materials and Methods: Chromatographic separation achieved isocratically on Phenomenex, Luna C18 column (5 μm, 150mm x 4.60mm) and acetonitrile: phosphate buffer (pH 7.0) in the ratio
stability based on the sagital profile of the spine. In Denis’ classification, the middle column provides the greatest mechanical stability and bears the greatest axial load of the spine
developed on a Shimadzu Class vp series HPLC system with a phenomenex C 18 column (150 x 4.6 mm, 5 μ) using a mobile phase mixture containing acetonitrile and ammonium
degradation products and the analyte was achieved on Ace-C18, 150 x 4.0 m.m column using a mobile phase consisting of a mixture of aqueous potassium dihydrogen phosphate and acetonitrile
impurities were achieved on Kromasil 100 C18 (150 x 4.6 mm i.d.), 3.5 μ column. The mobile phase consisted of buffer and acetonitrile (80 : 20 v/v). The flow rate ... maintained at 1.5 mL/min with a detection wavelength…
from aqueous solution using CAC as adsorbent has been achieved using fixed-bed column where the effects of important factor s such as the initial 2,4-D concentration, flow
hexane extract was separated by column chromatography using silica gel as adsorbent. The column was eluted by solvents in their increasing order of polarity. Compounds were isolated and purified ... repeated silica gel…
pollution, mutagenic substances or physical factors such as the depth of the water column. This population genetic study is the first for this species in peninsular Malaysia. The data from
Symmetry C18, 4.6 x 150mm, 5 mm, XTerra analytical column with flow rate of 0.8 ml/min with detection at 287 nm. An external standard calibration method was employed
HPLC. Chromatographic separation was performed on a Xterra C18 ( 4.6 X 100 mm ) column using a mobile phase of methanol and Potassium dihydrogen phosphate (50:50v/v) adjusted ... system conditions were maintained…
pharmaceutical dosage forms. Granisetron hydrochloride was chromatographed on a reverse phase kromasil C18 column (250 x 4.6mn; 5μm) in a mobile phase consisting of 0.05 M potassium dihydrogen phosphate
HPLC) method. The method utilized RPHPLC (Younglin with UV-detector) model and a column, 150mm ´ 4.6 mm, 5m (Symmetry, ODS- 3V, 150mm ´ 4.6mm, 5m). The mobile phases were comprised
industrial activities may pose a serious threat to the environment. A laboratory soil column experiments were conducted to determine the extent of Pb leaching from soil percolated with influent that ... clay loam soil…
caffeic acid and oleanolic acid using different chromatographic methods (i.e. paper, thin layer, and column chromatography). The structure of these compounds was determined by extensive IR, UV, and NMR spectroscopy
chromatographic separation was achieved on C18, 50 mm × 4.8 mm, 1.8-μm particle size column. The mobile phase contains a mixture of 0.2% ortho phosphoric acid and acetonitrile
HPLC system with the help of autosampler. The analysis was carried out using column 250 × 4.6 mm column packed with10-μm Spherisorb reversed phase octadecyl silane particles
Ammonium sulphate precipitation method and further purified by DEAE cellulose ion exchange column chromatography. High titre of more than 1:10000 antibodies were detected by Indirect antigen capture ELISA
with Photo diode Array (PDA) detector, Pump model 600E of Waters and Empower software. Column used for the separation is ODS (250 × 4.6 mm) with particle size ... with a flow rate of 1 mL/min on a C18 column. The…
subjected to further fractionation followed by pilot thin layer chromatographic (TLC) experiments and column chromatography. This yielded a pure, white, crystalline solid which resolved at Rf 0.65 upon