using a mobile phase consisting of methanol-phosphate buffer (60:40 v/v) at a rate of 1 ml per minute and using ultra violet detector (230 nm). Linearity
mobile phase. The flow rate was fixed at 1.5 mL/min. The linearity range for the proposed method was 0.25- 50μg/mL. Photodiode array detector was set at a wavelength
Diode Array detectors, Column used was Waters XTerra RP C18 column, 5 μm particle size, 250 mm × 4.6 mm i.d, at ambient temperature. The mobile phase consisting of Phosphate Buffer
using conductivity detector in single column mode. Desired separation was achieved within 20 min using mixture of 3 mM CH3SO3H+CH3CN (90:10) as mobile phase on Dionex
Mobile phase-B. High sensitive detection was achieved with “Applied Biosystems, Sciex, API-4000” Mass spectrometer and “API 4000, MDS Sciex, Toronto/Canada” Mass Detectors. As part of the method
5μm, with mobile phase composed of ammonium acetate buffer (20mM) and acetonitrile in 60:40 v/v ratio, pH 6.5. The analyte was monitored with UV detector at 265nm
lambda UV-visible detector is used for the quantification purpose. The analysis is carried out on a C18 column (250mm × 4.6mm; 5μm) at a mobile phase flow rate
with a (R, R) - Whelk- O-2 chiral column under reversed phase condition. Mobile phase was 50 mM potassium dihydrogen phosphate (pH = 2.6) and methanol [60:40, v/v] using ... standard. The flow rate was 1.8 ml / min…
phase composed of water: Acetonitrile (60:40) at a flow rate of 1.0 ml/min. The peak response time for caffeine was observed at 1.275 minutes using UV detector ... time can be decreased to less than 10 mins, the mobile…
molecular threshold photoelectron spectroscopy and threshold photoelectron photoion coincidence spectroscopy (TPEPICO) in the gas phase over the last fifty years will be reviewed. Emphasis will be placed on…
using solid phase cartridges and the analysis of the eluent was carried out using Atlantis T3 column (150 cm × 4.6 mm ID) and photo diode array detector set at wavelength
mobile phase comprising 0.01M Buffer: Methanol in the volume ratio of (40:60) was developed. The detection was carried out using a UV-detector set at a wavelength
mobile phase of Potassium dihydrogen phosphate: methanol in the ratio 30:70 v/v at a flow rate of 0.8 mL/min. using UV - Visible detector at the wavelength
based on reversed-phase high-performance liquid chromatography (RP-HPLC) using acetonitrile: phosphate buffer PH 6.8 (60:40v/v) with 1ml/min flow rate. The detector response was obtained
using mobile phase containing10mm Ammonium acetate PH:5.5 .The flow rate was 0.8ml/min and column temperature was 25°c.Benzyl chloride was detected using UV detector at the wave
mobile phase consisting of methanol: acetonitrile: 0.01 M oxalic acid dihydrate (5:18:77 v/v/v) in isocratic mode. Detection carried out by UV detector at wavelength
array (PDA) detector. TA in bovine, swine muscles and milk were analyzed using a C18 column (5 μm, 250 mm × 4.6 mm i.d.) and the mobile phase consisted of water
with mobile phase comprising 0.1% OPA: acetonitrile in 45:55% v/v at flow rate 1ml/min. Detection was carried out at 258 nm using PDA detector with injection volume
diode array detector in this study. A good separation of these preservatives was observed using InertSustain® Phenyl column and 0.1 % formic acid solution as the mobile phase. 2-Methyl
mobile phase contains 50Mm ammonium acetate in double distilled water. The instrumental setting is flow rate of 1 mL/ min, column temperature at 30oC, and detector wavelength