matter accumulation per plant were recorded. The data were analyzed by analysis of variance and linear or nonlinear regression analysis. The total chlorophyll content (CHL), carotenoids (CAR) and maximum quantum
zero crossing of ATV) where TELM showed considerable absorbance. The second method Q-analysis (absorbance ratio), involves formation of Q-absorbance equation using respective absorptivity values at 280.9 nm (isobestic…
conditions. Association of resistance traits with RGA-SSCP markers was evaluated using simple linear regression analysis. Three RGA-SSCP markers were found to be significantly correlated with anthracnose resistance…
developed a database for data storage and analysis. LeMBA fulfilled many prerequisites for a biomarker discovery platform, namely, high-throughput, sensitivity and linearity (1). We have applied LeMBA
linear in the concentration range of 100-800 ng/band for Thiocolchicoside and 600-4800 ng/band for Dexketoprofen. The method has been successfully applied for the analysis of drugs
adjusted with glacial acetic acid) (70: 30% v/v). The calibration curve was linear (r2>0.99) through the range of 0.2-1.2µg/ml. The lower limit of quantification ... accuracy, precision, recovery, sensitivity and…
immunoassay (PETINIA), which was not affected by the hook effect phenomenon. This method was linear from 0 to 150 mg L-1 (r2 = 0.987), with a detection limit ... system demonstrated its applicability to perform accurate…
ambroxol hydrochloride (AMB) in combined tablet dosage form by external standard method. The analysis was carried out using acetonitrile, methanol, 0.1% trifluoroacetic acid in the ratio ... respectively. The method was…
standard. Extraction of the drug from the plasma was carried out by precipitation method. Analysis was performed using Kromasil C18 column (250 �?� 4.6 mm; 5μ) with mobile phase consisting ... Chromatographic separation…
column was used in this study. The analysis was performed using the mobile phase: 0.1% acetic acid in acetonitrile and 0.1% acetic acid in water (90:10, v/v) under ... tuberosa extract was found to be 9.28 ±0.09%. The…
Analysis was carried out using Waters’ symmetry C-18 column with acetonitrile: methanol (80:20) as isocratic elution mode with UV detection (λ=210 nm). The method is pretty linear
then produces a heavy dew upon the land. The paper provides the underlying thermodynamic analysis for the process, together with a brief review of the essential concepts including: mass; weight ... series of…
gene action for earliness and yield traits in garden pea (Pisum sativum L.). Analysis of variance revealed the presence of highly significant differences among experimental genotypes indicating that the parents ... days…
calibration curve was linear in the concentration range 100 to 600 ng/ band for both the drugs. The method has been successfully applied for the analysis of drugs in pharmaceutical ... validated with respect to…
chosen in which the absorption maxima was observed at 229.25 nm and linearity was followed over the concentration range 0.5-50 μg ml-1 with regression equation is found ... used in which the maxima (343.32 nm) was…
water: methanol(50:50) is used to remove any residue from surface. The drug analysis was carried out on a Hibar ... respectively. The developed method was validated in terms of accuracy, precision, linearity, limit of…
sample preparation involved solid phase extraction using Varian Bond Elute C-18 cartridge. The linearity range of the proposed method was 4 to 375 ng/mL. The intra ... losartan were 101.7% and 100.0%, respectively. This…
sexually transmitted infections in St. Petersburg, Russia. Logistic regression models were applied for the analysis. Results: The comparison of data between men and women revealed a significant quadratic term…
Celecoxib were found to be 1.608 and 2.767min respectively and the linear regression analysis data for the calibration plots showed good linear relationship in the concentration range
range of 20 to 400 mg/dl for the bioelectrode. The linear regression analysis of bioelectrode revealed standard deviation and correlation coefficient of 11.6 μA and 0.992, respectively
proposed by Norden E. Huang, since it?s suitable to process nonstationary and non-linear signal, such as bio-signal. For our research, we take the heart sound signals ... input signal and the output signal. Compared…
aptamer was synthesised by Systematic Evolution of Ligands by Exponential Enrichment (SELEX). Bode impedimetric analysis indicated that the sensor platform (G2PPT-co-PEDOT) was a biocompatible polymeric semiconductor…
programming techniques and methods are being presented to optimize the solutions formed by spatial analysis tools. The previous work used the GA technique for multi-join operation in active data ... normal optimization…
with the help of PM5 calculations and geometry optimizations using Cache software. Multiple Linear Regression (MLR) analysis was performed to derive QSAR models using the descriptors, molecular weight (MW), conformation
concentrations of blinded plasma samples spiked with lumefantrine and had to submit their analysis reports to ACC for evaluation within 6 weeks. Each laboratory was provided with reference standard, internal ... were…
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.