terbinafine hydrochloride in water was found to be 283 nm. The drug follows linearity in the concentration range 5–30 μg/ml with a correlation coefficient value ... help of two analysts. Conclusion: The above method was…
detection was monitored at 210 nm. Results: The calibration curve for prasugrel was linear from 100 to 600 µg/ml. The inter-day and intra-day precision was found ... quantification of prasugrel in the dosage form, bulk…
Diode Array detector. Fenugreek seeds and two marketed herbal formulations were subjected for HPLC analysis of Trigonelline. Results: The RP-HPLC method was validated as per ICH guidelines ... found to be 5.00 ng/mL and…
analysis or absorption ratio method. Absorbances were measured at 256 nm (isosbestic point) and 276 nm (λmax of aceclofenac). Methods are validated according to ICH guidelines. Results: A linearity range
Contrast Enhancement is one of the most acceptable methods. Different contrast enhancement techniques i.e. Linear Stretch, Histogram Equalization, Region based enhancement, Adaptive enhancement are already available…
method produced linear responses in the concentration range of 10-100 μ g/mL of Rivastigmine. The method was found to be reproducible for analysis of the drug in tablet
multi-trait models. The model of analysis included the contemporary group as fixed effects and age of dam as a linear and quadratic covariable. In the random regression analyses, average
analysis (absorption ratio) method, which involves the formation of absorbance equation at 245 nm (isobestic point) and at 255 nm the maximum absorption of olmesartan medoxomil. The linearity ranges ... simultaneous…
ultraviolet region for the estimation of blonanserin in pure drug and pharmaceutical formulation. Linear response obtained was in the concentration range of 2-10 μg/ml with correlation coefficient ... There is no…
retention time for granisetron hydrochloride was 4.28 mts. The detector response was linear in the concentration of 16μg-26μg/mL with correlation coefficient of 0.9988. The percentage recovery of granisetron ... simple…
simple, selective, linear, precise and accurate RP-HPLC method was developed and validated for rapid assay of Ascorbic acid in Health drinks. Isocratic elution at a flow rate ... validated as per the ICH guidelines. The…
ethanol. This gave a good UV spectrum for ART with λmax at 242nm. HPLC analysis of this mixture revealed the presence of two prominent peaks. The peaks were further identified ... possibly be those of glycal and…
release characteristics for 8 h. In vitro drug release mechanism was evaluated by linear regression analysis. Floating matrix tablets based on the combination of polymers exhibited desired floating and prolonged
time for ethacridine lactate was found to be 4.41 min. The ethacridine lactate followed linearity in the concentration range of 2- 12 μg/mL (r2= 0.9980). The amount ... proposed method can be used for routine analysis…
absence of a UV absorbing chromophore and high polar nature of this antibiotic, the analysis of such compounds becomes a major challenge. Objective: To overcome these problems, a novel method ... rapid, specific…
phase (RP) column high-performance liquid chromatographic (HPLC) method has been developed for simultaneous analysis of eprosartan (EPR) and hydrochlorothiazide (HCT) in tablet formulations. Materials and Methods…
mobile phase. Densitometric analysis was performed at 260 nm. Result: Compact bands of ITZ were obtained at Rf 0.52 ± 0.02. Linearity (R2 = 0.9978), limit of detection (180.29 ng/band), limit ... peak purity of resolved…
tolperisone hydrochloride (TOLP) and etodolac (ETD) in a combined fixed dose oral formulation. The analysis was carried out using a phenomenax C-18, pre-packed column. A mobile phase containing ... minutes and 6.89…
were used to measure candesartan by using propranolol as an internal standard. Results: The linearity of the developed method was achieved in the range ... simple, rapid, accurate, cost-effective and specific; hence, it…
were calculated from the slope and intercept of the linear plots of lnK0 against 1/T. Analysis of adsorption results obtained at 303, 313, 323 and 333 K showed that
groups of adulterants are in the same data set, making the use of linear methods such as partial least squares regression(PLSR) difficult. Chemo metric MID-FTIR methods were used ... with good accuracy and better…
mass detector in multi reaction monitoring using ESI as an interface. The method was linear over a concentration range 0.1 to 250 ng/mL with a limit of Quantification ... range of 91.6-106.2%. Stability assessment was…
flow rate was set 1.0 mL/min and and analysis was performed at wavelength 237 nm using Photo Diode Array (PDA) detector at ambient temperature. The method was validated ... retention time for blonanserin was around 4.9…
respectively. The method was proved to be accurate and precise at linearity range of 2-36 µg/mL for paracetamol and 1-60 µg/mL for drotaverine hydrochloride with ... simplicity, accuracy and economical value, the…
Trichoderma harzianum using sugarcane bagasse under solid state fermentation. Statistical analysis of results showed that, the linear and quadric terms of these four variables had significant effects and evident…