High-volume clinical biobanks face challenges balancing time-intensive chain of custody (CoC) measures with timing, space, and personal demands. We at MD Anderson have developed a fully integrated clinical ... sample…
that the position sense decreased even if the shortening muscle during the position sense measurement involved muscle fatigue. It ensures that the increase in Joint Position Sense (JPS) was really ... studies give an…
This study aimed at extraction and evaluation of different terrain derivatives from airborne LiDAR measurements of reduced data volumes including slope, aspect and hillshade maps in addition to evaluation ... data…
drug-naive DSM-5 adult ADHD patients participated in this study. Saccade parameters were measured in the morning at baseline, and two weeks later following a single low dose administration ... baseline showed increased…
technique was developed for compressible flow applications. The new approach was used to accurately measure single-stream jet velocities and temperatures in compressible flow conditions for the first time. Later…
potentiate hypoglycemia risk. We assessed in such patients: whether flash interstitial glucose monitoring (iGM) measures correlate with capillary blood glucose (cBGL) levels, the prevalence of asymptomatic hypoglycemia…
next 24 hours and if any changes to predicted energy consumption, outside of usual error range, occur, it indicates that some equipment in energy system does not work properly ... internet without any big investment…
financial burden. There is an incidence of huge geographical variations, unavailable data, and documentation error, under reporting, unreported suboptimal fetal outcome and maternal morbidity. It is an integral part…
financial burden. There is an incidence of huge geographical variations, unavailable data, and documentation error, under reporting, unreported suboptimal fetal outcome and maternal morbidity. It is an integral part…
absence of visible ocular or visual pathway disease caused by an uncorrected refractive error, strabismus or form and light sense deprivation. Those with amblyopia may suffer from poor visual acuity ... undergone…
Statement of the Problem: Myopia is the most common cause of refractive errors in both children and adults in many countries. Comparisons of adult myopia prevalence across countries are complicated ... socioeconomic and…
confidence level. The simulated strains and deflections are validated using measurements from a second distributed fiber optic (strain) sensor and two linear potentiometers, respectively. The results demonstrate that…
than 5% at 95% confidence level. The simulated strains and deflections are validated using measurements from a second distributed fiber optic (strain) sensor and two linear potentiometers, respectively. The results…
Vickers, Knoop, Brinell (they are convertible into the depths), or that Rockwell and Shore measure the depth. Problems with cracks are not seen and reported (this does not mean cracks ... enforced” iteration of further…
standard or normal, cf. VIM: Traceability is “the property of the result of a measurement or the value of a standard whereby it can be related to stated references, usually ... analysis should offer more than only the…
measure of the risk-prone and risk-adverse decision attitude modelled by the function generating the synthetic indicator map and an estimation of the omission and commission errors that this
literature different generalized entropy measures are available for the engineering sciences and reliability theory. In the sampling theory, ranking methodology and Mean Square Error & Variance are widely used
best classification performance 88% accuracy, 81% sensitivity, 93% specificity and 0.85 F-measure. The error threshold value of 0.03 showed the nest results. These findings support the theory that patients
generally has difficulty to determine the optimum pre-hole shape. Many try and error is needed. In this study, we proposed that the method of estimation for optimum pre-hole ... analysis model is simple circle. After…
Inadequate sphygmomanometer maintenance and calibration is a cause for systematic error in BP measurements. Similarly errors in BP measurement arise when the cuff size is too small relative ... underestimate BP. The use…
electrocardiogram (ECG) is a diagnostic tool that measures and records the electrical activity of the heart in detail. Being able to interpret these details allows diagnosis of a wide range ... safe patients' life…
given period under given conditions. Software Reliability Growth Models (SRGMs) are used to measure the quality of the software. Many SRGMs assume that software reliability is a one-stage process ... imperfectly…
there are no evidence-based strategies to promote engagement of these patients in medication error prevention. Therefore, the purpose of this article is to report the feasibility, acceptability, and preliminary ... with…
with CPL-1 packed column showed good linear respondence toward measurement of H2/HD/D2 mixtures with mean relative error less than 4%, showing promising potential use of MOF material
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.