sodium and itopride hydrochloride in its pure and pharmaceutical capsule formulation. A gemini C18 column(4.6mm×25cm) in isocratic mode, with mobile phase potassium dihydrogen phosphate and acetonitrile
hydrochlorothiazide in tablet formulations is described. Separation was achieved on a gemini C18 column(4.6mm×25 cm), in isocratic mode, with phosphate buffer(pH 2.5), acetonitrile and tetrahydrofuran
flow rate of 1.0ml min-1 and detector was set at 220nm. The column selected was thermohypersil, C18, 5μm packing, 4.6mm×250mm and injection volume was 20μl
terbutaline sulfate, guaifenesin and bromhexine hydrochloride in a syrup formulation. A Phenomenex Luna C18 column, 250×4.6mm, 5μm in gradient mode, with mobile phase ammonium formate buffer
important to control the level of the same in the final API. The GC column used wasAT-WAX, 30mï‚´0.53mm, 1.0ïÂÂÂmfilmthickness and the instrument employed
enantiomeric separation of ï¢-amino-ï¢-(4-bromophenyl) propionic acid using donor- acceptor (Pirkle) column. The enantiomers of ï¢-amino-ï¢-(4- bromophenyl) propionic acidwere resolved on a 250ïà ... Whelk-…
sodium hydroxide was used as solvent. DevelopedHPLCmethod is reverse-phase chromatographicmethod using C18 column and methanol: water in ratio of 90:10 asmobile phase, at a flow rate
flowrate of 1.5ml/min.Ahypersil BDS 150 x 4.6mm, C18 column was used as a stationary phase. Quantification was performed using PDA detector at 270mm. The method showed good
target analytes such as sample size, pH, kind of buffer, elution solvent, etc column technique was used to preconcentraton of those compounds followed by their determination using flame atomic absorption
method was carried out on a Hichrom C18 (25 cm × 4.6 mm i.d., 5μ) column with a mobile phase consisting of acetonitrile: 0.5% triethylamine buffer (adjusted to pH 3.5 using
carried out on a PrincetonSPHER C18 (150 x 4.6 mm i.d. 5 μ) column with a mobile phase consisting of acetonitrile: phosphate Buffer (pH, 7.5 adjusted with orthophosphoric acid
pharmaceutical dosage forms. Sertraline HCl was chromatographed on a reversed phase C18 column in isocratic mode with a mobile phase comprising of acetonitrile, methanol and buffer (pH adjusted
distilled water and freeze-dried. Lyophilized proteins were loaded onto an ion-exchange chromatography column. Dialyzed- lyophilized proteins from the main peak of DEAE-Sephacel were applied ... column coupled to an…
position of that equilibrium and by GC/ MS where solvent separation in the analytical column seems to preclude shifts from the equilibrium reached at the injection port
carried out on a Phenomenex Gemini C18 (25 cm x 4.6 mm i.d., 5μ) column with a mobile phase consisting of acetonitrile: 20 mM octane sulphonic acid buffer (adjusted
combinations in pharmaceutical preparations and in human plasma. In LC methods, ACE C18 column with a mobile phase composed of methanol – phosphate buffer ... combination in pharmaceutical preparations and human plasma…
Princeton SPHER C18 (15 cm x 4.6 mm i.d., 5 ïÂÂÂ) column with a mobile phase consisting of acetonitrile: dipotassiumorthophosphate (adjusted to pH 7.5 using orthophosphoric acid
estradiol (EE) and levonorgestrel (LNG) in their binary combination. In LC method, Nucleosil C8 column with a mobile phase composed of acetonitrile-water (90:10, v/v) with UV detection
developed and validated for captopril tablets stability samples. The HPLC conditions were as follows, column: Luna C8, 5μm packing, 4.6 mm x 250 mm: UV at 220 nm: injection volume
bulk drug and in tablets. The determination was performed on a reversed phase column (ODS C18; 250x4.6 mm i.d) using a mobile phase(1.5 ml/min) consisting of potassium dihydrogen
HPLC separation could be undertaken on a reversed phase Accurasil SS C18 (5 ïÂÂÂm) column (25 cm x 4.6 mm i.d.) by using a mobile phase consisting of acetonitrile
For authors and organisers