audiometric as well as equilibriometric investigations. The results of the audiovestibulometric examinations - pure tone audiometry, vocal audiometry, and Brain Evoked Response Audiometry (B.E.R.A.), Cranio-CorpoGraphy…
recognized as an extra-renal complication of chronic kidney disease (CKD). Although pure-tone audiometry remains the conventional method for documenting hearing loss, a laboratorycentered approach may provide earlier…
patients and duration of the illness using tuning fork tests and pure tone audiometry. Aim: To study the hearing loss in type II diabetics and controls. Objectives:1. To study ... part in the study. They were evaluated…
especially if there is background noise, but have normal hearing thresholds on pure tone audiometry. It accounts for nearly 10% of patients presenting to ENT clinics. Various studies have cited ... patients who…
populations between age groups of 6 months to 70 years were screened. Pure tone audiometry was done simultaneously. It was found that the prevalence of hearing loss in the community ... population with 63.31% failing…
through five stations: collection of demographic data, otoscopy, screening with hearing screener device, screening audiometry and counseling. Ambient sound was maintained at 50 dBA or less during testing. The hearing…
test findings in group A: butterfly calorigrams, 71.86%; stepping craniocorpography, 72.01 %; and pure-tone audiometry of bone conduction, 37.66% in the right and 47.07% in the left ear. Among group ... findings were…
application of slow vertex response audiometry (cortical evoked response audiometry), mainly in the diagnosis of pseudohypoacusis, is reported. This procedure is of interest in forensic audiology
Owing to its subjective nature, behavioral pure-tone audiometry often is an unreliable testing method in uncooperative subjects, and assessing the true hearing threshold becomes difficult. In such cases, objective…
patients (40 females and 25 males), received treatment. The outcomes of pure-tone audiometry were evaluated preoperatively, one month postoperatively, and at later stages to assess the long-term impact
healthy subjects; 5 males and 15 females served as controls. Pure Tone Audiometry (PTA), air and bone conduction threshold were done for all volunteers. Results: PTA and air conduction threshold
monitor the patients. At the end of the second post-treatment week, pure tone audiometry and tympanometry were performed again. Normal otoscopic results, a type A tympanogram, and enhanced pure
different frequencies and intensities. There are several types of hearing tests, including puretone audiometry, speech audiometry, and tympanometry. Pure-tone audiometry measures a person's ability to hear different…
audiological profile of a population in the Amazon, using data from the results of audiometry. Methods: The study is characterized by being a crosssectional, observational and retrospective study, with descriptive
otologic examination using Welch Allyn Digital Macro-View Video Otoscope, diagnostic pure tone audiometry using GSI 61 calibrated to ANSI (2004) specification. Participants also had middle ear examination using
Those who failed in the retest were asked to report for Brainstem Evoked Response Audiometry (BERA). Those who were diagnosed as having hearing impairment were advised auditory rehabilitation as well
dysfunction of Eustachian tube which were elicited with the help of history, pure tone audiometry and tympanometry and 20 patients with persistent dysfunction of Eustachian tube even after 3 weeks ... under study have…
Brainstem Evoked Response Audiometry (BERA) is the gold standard electrophysiological investigation for the assessment of synchrony of the auditory pathway. There can be variations in the synchrony based on many
Introduction: High frequency audiometry may contribute to the early detection of hearing loss caused by ototoxic medications. In the treatment of patients with cystic fibrosis, there are many ototoxic drugs ... language…
months and 1 year for graft status and hearing outcome by pure tone audiometry RESULTS In 100 cases of type 1 tympanoplasty performed, overall success rate of 88% of graft
procedures, for both groups, were performed in two sections: anamnesis and conventinal pure tone audiometry. Results: Normal hearing thresholds of control and study group evinced that study group had worsening
economic status working at a shipbuilding enterprise. An interviewer‑administered questionnaire was followed by audiometry. Values were presented as percentages, Mean (SD) and odds ratio (OR) and its 95% confidence
mastoidectomy has almost no effect on graft acceptance and hearing gain in pure tone audiometry. CONCLUSION This study was planned to find the effect of cortical mastoidectomy in tympanoplasty type
analysis of auditory pathway by Brainstem Auditory Evoked Response (BAER) and with Pure Tone Audiometry (PTA) in type 2 diabetes. To compare the same in healthy individuals with euglycaemia. Materials