solid phase extraction (SPE) sorbent that was fabricated in our laboratory. Current molecular diagnostic assay methods face a challenge of lack of direct and accurate analysis despite employing sensitive, hyphenated…
sensitive stability indicating high-performance thin-layer chromatographic method was developed and validated for quantitative determination of Acyclovir in tablets. Chromatographic separation was performed on precoated…
using dichloromethane: water: methanol: acetonitrile (3:1:3:4, by volumes) as a developing mobile phase containing 1 gm % Ninhydrin as a coloring agent. Densitometric measurements were done in a fluorescence ... mobile…
complex compound hexyl benzylcarbamate (HBC) by reaction with benzylamine. This method provided good sensitivity for quantification of hexyl chloroformate at a concentration ... particle packed in 4.6 x 50 mm column)…
subjected to FTIR analysis of the different solvent extracts to know the functional groups.Reverse phase high-performance liquid chromatographic (RP-HPLC) method with gradient elution was adapted to fractionate…
eluents in HPLC has shown excellent potential. We have developed a novel, rapid and sensitive microemulsion HPLC (MELC) method using oil-in-water microemulsion mobilephase for the simultaneous determination…
phase was pumped at a flow rate of 1 mL/min and detection was made at 221 nm with UV dual absorbance detector. The proposed methods are highly sensitive, precise
size (SYMTA, Madrid, Spain) protected by a 0.2-μm on-line filter. The mobile phase consisted of a combination of 0.2% formic acid and 0.3% ammonia in MilliQ water ... volume injected into the chromatographic system was…
complex compound hexyl benzylcarbamate (HBC) by reaction with benzylamine. This method provided good sensitivity for quantification of hexyl chloroformate at a concentration ... particle packed in 4.6 x 50 mm column)…
sensitive and specific ultra-performance liquid chromatography combined with electrospray ionization (ESI) tandem mass spectrometry (UPLC-MS/MS) method, operating in the positive ionization mode, for the determination…
gastrointestinal system since the incretin receptors are not affected directly. Practical, selective and sensitive methods are demanded for the determination of sitagliptin, vildagliptin and saxagliptin from tablets…
preparation of urine and blood serum for analysis provided the decrease in detection limits for hydrophobic and hydrophilic analytes. Application of watersoluble oligosaccharide derivatives hyperbranched…
selective and sensitive liquid chromatography tandem mass spectrometry method (LC-MS/MS) has been developed for determination of Hypophyllanthin (HPT) and Silibinin (SBN) in human plasma. Sertraline hydrochloride was…
high sensitive analytical method for determination of the trace estrogens in environmental water is important for environmental safety. In this study, a novel temperature-controlled liquid phase microextraction (TC-LPME…
with properly optimized samples pre-purification (involving e.g., liquid-liquid or solid phase extractions) and sensitive detection (e.g., fluorescence or colour staining) can be very helpful to investigate various…
very sensitive stability indicating RP-HPLC method has been developed and validated for iloperidone in the presence of its degradation products generated in studies of stressed decomposition. Iloperidone is recently…
simple and sensitive ion chromatography method has been developed for the simultaneous determination of dimethyl sulfate and diethyl sulfate contents in Metoprolol tartrate drug substance. Efficient chromatographic…
rapid and sensitive capillary electrophoresis (CE) method was developed for the determination of piperidine and diethylamine content in Entacapone drug substance using a background electrolyte(solution containing…
drug and pharmaceutical formulations was developed and validated in the present study. The mobile phase consists of a mixture of Buffer, Methanol, and Acetonitrile in the proportion ... accuracy, precision, robustness…
rapid and sensitive reverse phase high-performance liquid chromatographic (RP-HPLC) method has been developed and validated successfully for the simultaneous determination of biologically active and thermally stable…
subjected to stability studies using optimized method condition to enhance low level of detection with minimum acquisition time. Successful separation of p-Toluenesulfonic acid was achieved from the related impurities…
monitoring progression of the disease. Further, cancer biomarkers play an important role during all phases of drug discovery and development and in guiding early decision in clinical trials. Real-time ... qPCR)…
carbon support materials are combined with a proton conducting polymer. The microstructure, the phase distribution and the occurring interfaces are key parameters which determine the performance. Due to the size…
Curcumin levels are generally low so that the required bioanalytical method is selective and sensitive. A simple, specific and rapid UPLC-MS/MS method has been developed and validated ... Acquity® Waters; 0.15% formic…
sensitive, reproducible, and rapid stability indicating RP-HPLC method was developed and subsequently validated for simultaneous determination of both benazepril (BENZ), benazeprilat (BENZT), and amlodipine (AML) in…