used a reversed-phase C18 column with a mobile phase delivered to the analytical column according to a gradient program starting at a composition of ammonium acetate ... changes to 90% of acetonitrile at 11 min…
Authors developed a simple, highly sensitive, selective, rapid, rugged and reproducible liquid chromatography–tandem mass spectrometry method for the quantification of Cilostazole (CZ) in rat plasma using Cilostazole…
simple, selective, rapid, precise and economical reverse phase high pressure liquid chromatographic method has been developed for the estimation of valsartan (VALS) from pharmaceutical Tablet dosage form. The method…
Chiral OD-H 25 cm x 4.6 mm x 5.0μ (Cellulose based) column with mobile phase Hexane: Ethanol: Diethyl amine (95:5:0.1v/v),was used. The detection ... linearity of Levobetaxolol shows regration coefficient of 0.9999. The…
using LC-MS (ESI). Chromatography was performed on a C 18 analytical column, the mobile phase used was Acetonitrile-10mM Ammonium acetate in the ratio ... azithromycin (Internal standard) and amlodipine respectively…
Levofloxacin has low concentration in plasma, thus it requires sensitive and selective analysis method. Plasma drug analysis often uses many sorts of anticoagulant to get plasma as analytical matrix. Citrate…
Although silica-based columns are still the most frequent in HPLC analyses, the sorbents based on metal oxides have already found their place in liquid chromatography. Compared to silica ... compare with silica phases…
necessary component of early phase drug development. Objective: The study’s design involves selecting an RP-HPLC method for drug estimation followed by assessments of the kinetics of drug degradation ... HPLC series…
simple, rapid, selective isocratic normal phase liquid chromatographic (NP-LC) method was developed for the chiral purity of Lacosamide ((R)-2-acetamido-N-benzyl-3- methoxypropionamide) and its undesired…
simple, economical, precise, and selective Reverse gradient Phase High-Performance Liquid Chromatography (RP-HPLC) method has been validated and developed to estimate related impurities of Nebivolol (NEB) and Valsartan…
simple, selective, linear, precise and accurate RP-HPLC method was developed and validated for rapid assay of Cefaclor in Bulk and Pharmaceutical tablet Formulation. Isocratic elution at a flow rate ... employed on…
objective of present work was to develop and validate a simple, fast, precise, selective and accurate RP-HPLC method for the simultaneous determination Ramipril(RAM), Aspirin (ASP) and Simvastatin ... three drugs was…
Introduction: A selective, specific, and sensitive “Ultra High-Pressure Liquid Chromatography” (UPLC) method was developed for determination of candesartan cilexetil impurities as well asits degradent in tablet…
bulk. In this method a C18, 25 cm 5μ 4.6 mm ID (Oyster) column with mobile phase consisting of Sodium acetate buffer pH 3.0: Acetonitrile (70:30) was used ... linearity of Eprosartan shows regration coefficient of…
simple, selective, rapid and precise reverse phase HPLC method has been developed for the standardization of Caesalpinia digyna root (Family: Leguminosae) using Bergenin as an analytical marker. The method…
Removal of the solvent under reduced pressure, the residue left behind was subjected to column chromatography on silica gel (200-400) and hexane / ethyl acetate as eluent, which gave ... disproportionate to HBr and…
simple, selective, linear, precise and accurate RP-HPLC method was developed and validated for rapid assay of Dobutamine in Bulk and Pharmaceutical tablet Formulation. Isocratic elution at a flow rate ... employed on…
simple, selective, linear, precise and accurate RP-HPLC method was developed and validated for rapid assay of Repaglinide in Bulk and Pharmaceutical tablet Formulation. Isocratic elution at a flow rate ... employed on…
accurate, sensitive, selective and precise stability indicating Isocratic RP-LC method and UV-visible Spectroscopic method were developed for the quantitative determination of enzalutamide in bulk and synthetic mixture…
simple, selective, linear, precise and accurate RP-HPLC method was developed and validated for rapid assay of Benzoic acid in Bulk and Pharmaceutical Formulation. Isocratic elution at a flow rate ... employed on…
with an phenomenex luna 5 μ CN 100R, 250×4.60 mm 5 micron size column, ambient temperature with a low pressure gradient mode with mobile phase containing acetonitril ... rate was 1 mL min-1 and eluent was monitored at…
simple, selective, linear, precise and accurate RP-HPLC method was developed and validated for rapid assay of Solifenacin in pharmaceutical dosage form. Isocratic elution at a flow rate ... employed on XTerra C18 (150 ×…
simple, selective, rapid, specific and stability indicating reversed phase high performance liquid chromatography (RP-HPLC) method for the determination of doxofylline in the pharmaceutical dosage form has been…
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.