Validated RP-HPLC Method for the Determination of Indapamide in Bulk and Tablet Dosage Form
phase, pumped in to the column at flow rate of 1.0 mL min−1and the detection of eluent from the column was carried out using variable wavelength UV detector
Articles, journals and conferences in one search. An exact title, DOI or ISSN is listed first.
In the search box: "exact phrase" · -leave out · OR · prefix* · title: author: journal:
phase, pumped in to the column at flow rate of 1.0 mL min−1and the detection of eluent from the column was carried out using variable wavelength UV detector
mobile phase composed of 0.1% formic acid : methanol (20:80 v/v), at a flow-rate of 0.2 mL/min AQ and AQIS were detected with waters TUV detector
phase Orthophosphoric acid buffer and Methanol in the ratio of 600:400v/v. The flow rate was 1.0 mL.min-1 and the separated drugs were detected using UV detector
mobile phase [Acetone-M: Buffer-1(40:60% v/v)] and diluent as [Acetone-M: Water (90:10% v/v)] .Carbocisteine was chromatographed and analyzed by MS Detector. The analytical
phase consisting of pH 3.3 Phosphate buffer: Acetonitrile (30:70 %v/v). The flow rate was 1.0 mL/min and eluents were detected at 280 nm using PDA detector
detector computed tomography (CT) scan in Alzahra Hospital in 2017 for various complaints other than SMA syndrome. CT scans were performed by the standard protocol including a plain phase scan
phase used was a mixture of 0.1% OPA buffer 300 ml (30%) and 700ml Acetonitrile (70%) at isocratic mode and eluents were monitored at 309 nm using PDA detector. Results
phase at a flow rate of 1.5 mL/min and detection UV wavelength of 225 nm. The method was validated according to USP Category I requirements. Linearity for detector response
phase was composed of acetonitrile and phosphate buffer pH 4.5 in the ratio 50:50 at a flow rate of 1.0 mL/min. Elutes were analyzed using PDA detector
phase in a gradient mode of elution at a flow rate of 1.0 mL/min at 50°C. The column effluents were monitored by a photo diode array detector
Reversed Phase Liquid Chromatography (RP-HPLC). It takes into consideration both parts of amphiphiles: the hydrophilic and lipophilic moieties of the molecule. The double detection using Diode Array Detector
detector for simultaneous quantification of malachite green (MG) and itsmetabolite, leuco-malachite green (LMG), in cultured eel is described. TheHPLC-PDAwas performed on aC4columnwith anisocratic mobile phase. Analytes…
phase is Acetonitrile and Water (90:10, v/v). The instrumental settings are at a flow rate of 0.8mL/min; the column temperature is 25°C and detector wavelength
phase combination of 1% Orthophosphoric acid and Methanol (60:40) at a flow rate of 1.0 mL min-1 and the detection was carried out by using UV detector
array detector (UPLC-PAD). Psoralea corylifolia Linn. seeds were collected from Pharmacy, Central Research Institute of Unani Medicine, Hyderabad and extract was analyzed by using a reverse-phase Waters Acquity
phase of acetonitrile: water (60:40 v/v) at a flow rate of 1.0 mL/min. The injection volume was 20 μL and elute was analyzed with UV detector
phase with injected volume 100 μl with flow rate 1.5 ml/min over the concentration range 1.0-2.9 μg/mL were determined at 227 nm using UV spectrophotometer detector
phase was (methanol: phosphate buffer pH 3.0) ratio in gradient flow. Elution was accomplished using a flow rate of (1mL/min). Detection was carried out using a UV detector
detector. A dedicated analysis procedure to extract the time course of one or more regions of interest on the acquired MRI foot images, allows identifying the mechanical action phase
separations are insufficient when the polar part of the molecules is the focus. Normal phase (NP) LC can achieve sufficient separations, but tends to be slow, intolerant of high sample ... better NP separation. While…
major degradants (impurities) of nebivolol hydrochloride by acid hydrolysis and by oxidation. The mobile phase comprising of methanol:water [80:20v/v, (pH 7.2, adjusted by adding 0.2 M glacial ... detection was…
development of the chromatographic analysis of dog plasma samples by utilizing the mobile phase of the HPLC-UV consist of a mixture of 0.1% water, 88% formic acid ... column utilizing a flow rate of 0.7 mL min-1 and…
Haloperidol and Loratidine (Internal Standard) was achieved using C18 column as stationary phase. Mobile phase consists of Acetonitrile and Water (50:50), pH-2.5 with 0.1% Acetic Acid ... Detection was carried out at…
drugs was achieved on a Phenomenex column (200mm×4.6 mm, 5μm). The mobile phase consisting of a mixture of 0.1 M phosphate buffer adjusted to pH 5.5 and acetonitrile ... flow rate of 1.0 ml/ min. Detection was performed…
phase transitions related with its breaking can lead to macroscopical primordial nonlinear structures, like clouds of massive primordial black holes, whose coalescence might have been observed in gravitational wave…
For authors and organisers
Find the right journal for your paper and submit your manuscript.