specificity than usual, and this was achieved either through multidimensional chromatography or through high resolution mass spectrometry (accurate mass determination) or both. The bacterial endpoints consisting of…
Targeted analytes were determined byHPLC/fluorescence detection in some cases and confirmed through high resolution mass spectrometry (accurate mass determination) or both. The bacterial endpoints consisting of…
diethyl amine in the ratio of 75: 25: 0.05 (v/v/v). Good resolution viz. 3 min between R- and S- forms of Darifenacin was achieved with Immobilized chiral stationary
phase at a flowrate of 1.0mLmin-1. The elution timewas approximately 15min. The resolution (Rs) between the enantiomers was greater than 3.0. The limit of detection (LOD) and limit
chromatographic conditions were optimized to avoid interferences fromthe excipients aswell to achieve acceptable resolution between dihydroartemisinin, imput\rity A and and artemether and also well between
peaks of degraded product were resolved from the standard drug with significantly high resolution. This indicates that the method is reproducible and selective for the estimation of the said drug
gated CCD detection system. Wavelength calibration of the spectrometer is done to ascertain resolution and proper identification of elements. Synthetic standard solutions containing 21 metal impurities were prepared for…
detection at 252 nmat a flowrate of 2.5mLmin-1. In the developedHPLCmethod the resolution between Efavirenz and its enantiomer was found to be greater than 4.0. Regression analysis shows
flow rate of 0.5 mL min-1. In the developed RRLC method the resolution between Stavudine and its two potential impurities was found to be greater than 4.0. Regression analysis
acetonitrile and methanol, asmobile phase at flowrate of 1.2 mLmin-1 enabled acceptable resolution of pioglitazone and glimepiride frompossible impurities.UV detectionwas performed at 230nm. The developedmethod was…
nmwith a flowrate of 0.4mLmin-1. In the developed UPLC method the resolution (Rs) between Zaleplon and its all degradants obtained from forced degradation studies were found
mobile phase with a flowrate of 0.5 mLmin-1. The resolution (Rs) between the enantiomers was found to be greater than 4.0 and interestingly the R-enantiomer was eluted prior
nmat a flowrate of 0.5mLmin-1. In the developed RRLCmethod the resolution between Ramipril and its four potential impurities was found to be greater than 3.0. Regression analysis shows
Thewavelength of detection was 260 nm. The proposed chromatographic method gave good resolution of the drug in plasma. Felodipine eluted at retention time of 9.94 min. The linearity of themethod
butyl oxy carbonyl) amino-1,6-diphenyl hemi succinic acid (S-BOC amine). Good resolution with RS > 3 was obtained using cellulose based chiral stationary phase, chiralcelOD-H column
method has been developed for the separation of R-Naproxcinod from S- Naproxcinod. Good resolution viz. Rs > 3 between R- and S- forms ofNaproxcinod was achievedwithChiralcelOD
benzoic acid. Considerable degradation was observed under acid, base and oxidation conditions. Good resolution between the peaks corresponding to impurities produced during synthesis, degradation products and the…
detection was carried out at wavelength 230 nm. The chromatographic resolution between its degraded products was found to be greeter than three. The buclizine hydrochloride was subjected to stress conditions
node. Cultures grew Mycobacterium tuberculosis. Anti-tubercular therapy was initiated and resulted in gradual resolution of symptoms. Conclusion Pancreatic tuberculosis is rare and is frequently confused with pancreatic…
than 20,000 U/L). The cyst was treated with percutaneous drainage with complete resolution of the cyst. Conclusion In the setting of pancreatitis, intrahepatic pancreatic pseudocyst should be considered
communicating with the pseudocyst cavity, and pancreatic duct stenting was performed. There was complete resolution of both the pseudocyst and pancreatic duct fistula. Follow-up computer tomography performed 3 months
looking for solutions to problems through workshops, retreats and symposia whose outcomes and resolutions are never implemented but left on shelves to gather dust
notion. Sacred Monument does not give any rigt to women. Aged Sage present some resolution offers to convince women. But these offers are not accepted by men. Women resist
chromatographic method has been developed for the determination of tamsulosin hydrochloride pellets 0.2%. Good resolution was achieved with inertsil ODS 3V (5 microns, 15 x 4.6 mm) column
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.