Shimadzu UFLC, C 8 (250×4.6 mm, 5 μm) column with a mobile phase consisting of 0.03 M potassium dihydrogen ortho phosphate buffer (pH 3), acetonitrile in the ratio ... with a flow rate of 1.2 mL/min. The analyte was…
pharmaceutical dosage form in the presence of its impurities and degradation product. The mobile phase used consisted of Buffer: acetonitrile (90:10 %v/v) with pH 3.6 (adjusted with ... rate 1.0ml/min in isocratic mode…
performed on C 8 (250×4.6 mm, 5 μm) column with a mobile phase consisting of 0.03 M potassium dihydrogen ortho phosphate buffer (pH 3), acetonitrile in the ratio ... with a flow rate of 1.2 ml/min. The analyte was…
particle size in isocratic mode with mobile phase comprising of phosphate buffer (pH 3.0), acetonitrile and methanol in the ratio of 50:25:25 v/v. The flow rate ... detection was carried out by UV-PDA detector at 230…
using Phenomenex Hyper clone BDS C18 (5.0μm, 250Ã?4.6mm) column using mobile phase Acetonitrile (A) and Ammonium formate buffer (B) in the ratio 40:60, pH4.0 adjusted with ... rate of 1.0ml/min and the eluent was…
based on the differential affinities of sam ple molecules for the mobile and stationary phases within a chr omatographic column. HPLC is recognized for its high resolution, accuracy, and efficiency ... including…
separations were carried using Phenomenex C18 column (4.6x250mm,5µm) column with a mobile phase composition of 0.1 M Ammonium acetate:acetonitrile (60:40) have been delivered at a flow ... detection was carried out…
pharmaceutical dosage form. The quantification was carried out using C18 column and mobile phase consisting of 0.067 M phosphate buffer at pH 6.5: acetonitrile : methanol ... separation was performed at ambient…
analysis was done on a Merck C18 4.0 mm× 250 mm, column with mobile phase consisting of 0.1%phosphoric acid(pH adjusted to 2.5 with triethylamine) - acetonitrile ... Quantification was carried out using a photo-diode…
particle size) column in an isocratic mode with mobile phase containing phosphate buffer (adjusted to pH 5.5 with dilute othophosphoric acid and acetonitrile in the ratio ... flow rate of 0.8 ml/min. The analyte was…
Eclipse Plus column (100 x 4.6 mm x 3.5μ particle size) containing mobile phase of Phosphate buffer PH 2.5 (adjusted with diluted ortho phosphoric acid) and methanol ... flow rate of 1.0mL/min. The analyte was monitored…
bulk drug and tablet dosage form. The drug was separated using a mobile phase acetonitrile: water, (5:95 v/v) on an Agilent, TC C18 (250 × 4.6 mm) 5µm column ... ambient temperature and detection was performed at 263…
using BDS Hypersil C8 Column (100 x 4.6 mm, 5 µ) and the mobile phase of potassium dihydrogen phosphate (pH-2): methanol. Isocratic elution with a flow rate ... responses were measured at 244 nm by using Waters PDA 2998…
method was developed on Phenomenex Gemini C18 250´ 4.6mm, 5μm column using mobile phase as 0.02M ammonium acetate buffer pH 4.5 - Acetonitrile ... detection was carried out at 241 nm using photo-diode array detector…
fumarate in tablets. Chromatographic separation was achieved on a C18 column utilizing a mobile phase of buffer/acetonitrile (75:25, v/v, pH 5.6) at a flow rate ... room temperature. Detection was carried out at 226 nm…
determination of amino acid. A high performance liquid chromatography (HPLC) method with UV detector is developed for determination of individual 17 Amino acids content in bulk drug substance without derivatisation…
sample preparation step - for separation and enrichment, and high performance techniques for quantifications. Solid phase extraction (SPE) has been proved to be an effective sample pretreatment method due to high…
using Luna Phenyl Hexyl 150 mm × 4.6 mm, 5 µ column and the mobile phase containing 0.1% TEA pH-2.5/OPA and Acetonitrile in the ratio ... detection was carried out by absorption at 263 nm using a photodiode array…
separations were carried using Inspire (4.6 × 150 mm, 5 m) column with a mobile phase composition of 0.1% OPA buffer and Acetonitrile (30:70) have been delivered at a flow ... detection was carried out using waters HPLC…
mobile phase elution order at a flow rate of 1.0 mL/min. The mobile phase was buffer [0.1 %v/v solution of triethylamine in milli-Q water with ... acid)] and methanol in the ratio of 80:20. Detection was performed with…
column RP C- 18 (250 mm X 4.6 mm X 5 micron) using mobile phase mixture of Methanol &10 mmol dihydrogen phosphate buffer (the pH -2.5 adjusted with orthophosphoric acid ... flow rate of 1 ml/min, &analysis was screened…
potassium dihydrogen orthophosphate buffer in ratio of 35: 65 v/v as the mobile phase with a flow rate of 1 ml/min and injection volume of 10µl. Chromatographic separation ... 5µm) analytical column and the effluents…
silica, column 250 x 4.6mm internal diameter was 5- µm), using mobile phase of composition of tri-ethylamine buffer (pH 5.00): acetonitrile (50:50 (v/v)). The flow rate ... peak was observed at about 6.13 minute as…