separation was achieved on an XTerra C18 column in an Isocratic Mode. The mobile phase was composed of phosphate buffer (25 %) [pH 3.0 adjusted with OPA] and methanol ... rate was monitored at 1.0mL per min. The…
analyte detection. The usability of acoustic sensors requires specific knowledge relating to the sensing mechanism, the properties of different acoustic wave modes and the criteria for selection of sensitive layers…
bulk and commercial formulations was developed and validated in the present study. The mobile phase consists of a mixture of Methanol and water in the proportion 70:30 and adjust ... precision, robustness, detection and…
phase and a binary mixture of 20 mM Sodium acetate buffer (pH 4.0 ± 0.05) and methanol in a ratio of 30:70 v/v was used as mobile phase ... condition at a flow rate of 1.0 mL/min of the mobile phase and the wavelength…
sensitive, robust and reproducible method for the simultaneous estimation of Arterolane maleate and Piperaquine phosphate in formulation was developed using Reverse phase high performance liquid chromatographic method…
used at ambient temperature using mobile phase consisting of acetonitrile: 30mM phosphate buffer (60: 40 v/v) pH adjusted to 3.5 ± 0.02 with ortho phosphoric acid gave a symmetrical, sharp ... peak at (tR= 7.02 ± 0.05…
simple, sensitive and accurate isocratic reverse phase high performance liquid chromatography method was developed for simultaneous determination of montelukast sodium and levocetirizine dihydrochloride in tablets. The…
phase A and acetonitrile in the ratio of (76:24 % v/v) as mobile phase B. The compounds were eluted at a flow rate of 1.0 ml/min. The method ... conference Harmonization (ICH) guidelines. The validation characteristics…
dogs, and Eggbeaters®.This method involved sample homogenization, followed by polymeric reversed solid phase extraction, evaporation, and reconstitution.Determination and quantitation of L-abrine and ricinine was…
formic acid solution as the mobile phase. 2-Methyl-4-isothiazolin-3-one and 5-chloro-2-methyl-4- isothiazolin-3-one were detected in 16 samples, including the sample ... Octyl-4-isothiazolin-3-one was detected in one…
method of highly sensitive and highly selective multicomponent simultaneous analysis is indispensable for detecting and quantifying these products. Here, I summarize the findings of previous research and case study…
diameter of 12 nm through a coprecipitation method and used as the matrix solid-phase. Then, the ECL targets of Ru(bpy)2(dcbpy)NHS were successfully synthesized and labeled ... stable ECL signal, we designed a novel…
Transplant recipients who have sensitizing events such as pregnancies, blood transfusions and previous transplants often develop antibodies directed against human leukocyte antigen (HLA)-molecules of the donors’ organs…
adopted for optimizing chromatographic conditions, especially the method robustness by selecting organic phase composition, mobile phase flow rate and strength of tetra butyl ammonium hydrogen sulfate solution as the…
using mobile phase of a mixture of 80 volumes of Methanol: 10 volumes of Acetonitrile and 10 volumes of Water with detection of 256 nm. Linearity was observed in the range ... results show that the method was found to…
rapid, accurate, linear, and sensitive RP-HPLC method has been developed and validated for estimation of Clonazepam in the bulk and Pharmaceutical Dosage Form. The chromatographic separation was performed ... size)…
columns maintained at 30°C with a flow rate 1 ml/min. The mobile phase was 87.1% aqueous orthophosphate buffer 15 mM (adjusted to pH 3 with orthophosphoric acid ... butanol, all w/w. The nifedipine and internal standard…
complicated urinary tract infections. Ertapenem was separated on reverse phase C18 column within the analytical runtime of 2 min. Detection and quantification of ertapenem was based on multiple reactions monitoring…
simple, sensitive, Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) method was developed for the determination of Trimipramine maleate in human plasma using Opipramol dihydrochloride as internal standard (ISTD…
selected intervals. Ultra-sensitive hyphenated HPLC linked to ICP-MS was deployed to monitor these effects. Elution followed by mass spectrometry for simultaneous detection was conducted for convenient resolution…
simple, low cost and highly sensitive method based on cloud point extraction (CPE) used for separation/preconcentration of Nickel, Copper, Cobalt and Chromiumhas been described.After ... complexation with ligand 4-…
Asimple, rapid and sensitive RP-HPLCmethodwas developed and validated for the quantification of Dipyridamole in bulk drug and tablet formulation. The separation was achieved on a Inertsil X-terra ... mobile phase…
tablet dosage formon RP C18 BDS column (250mm×4.6 mm, 5µm) with a mobile phase consisting of A: Triethylamine (pH 3.0) adjusted with ortho phosphoric acid, B:ACN, with ... with a flow rate of 1.4 ml/min, UV detection at…
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.