reducing power assay. The different fractions were isolated from hydroalcoholic extracts by using column chromatography. The Flavonoids fractions were investigated for anti-inflammatory and anti-arthritis activity in…
indicates that an effective separation can be achieved by ammonium modified Chelex-100. The selectivity of Chelex-100 for Cu and Ni ions not only depends on its thermodynamic complexation ... stripped out, but 100% of…
stable-isotope labeling and Mass Spectrometry (MS) measurement. Briefly, we developed a highly selective and sensitive liquid chromatography?ion trap mass spectrometry (LC?MS/MS) method for identification and…
Simple, precise, rapid and selective reverse phase high performance liquid chromatographic (RP‐HPLC) methods have been developed and validated for the assay determination of Methylcobalamin 1500 mcg and Alphalipoic acid…
chromatographic separation was achieved on Lichrospher 100 RP-18e, 250 x 4.0mm 10μ column from waters-2998 isocratic ode, with simple mobile phase combination of phosphate buffer : methanol : water ... retention time of…
selective, sensitive, liquid chromatography mass spectrometry/ mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of Ziprasidone in human plasma by using Ziprasidone D8 as internal…
major catabolic products of cholesterol bile acids facilitates absorption of fats in intestine. A selective, sensitive MRM based liquid chromatography/ tandem mass spectrometry method has been developed and validated…
separation was performed on a symmetry C18 (4.6 x 100 mm, 5mm, Make: Phenomenex) column in an isocratic mode with the mobile phase consisting a mixture of Phosphate Buffer: methanol ... rate of 0.8 mL min-1 and eluents…
Successful separation of the drugs from the degradation products was achieved on ACE C18 column (250 mm×4.6 mm, 5 μm) with 65:35 % (v/v) potassium dihydrogen phosphate ... limits of detection and quantitation…
tetrahydrocarbazole hemisuccinate], an antimigraine drug. The enantioseparation was achieved on a Protein based Cellobiohydrolase column (Chiral-CBH) using an isocratic mobile phase consisting of 10mM dihydrogen…
estimation of rilpivirine. The HPLC analysis was carried out on Waters ODS (C8) Column, 250 mm x 4.6 mm in isocratic mode with a mobile phase of acetonitrile ... linear over a concentration range of 5- 30 μg/ml. The…
Simple, linear, precise, accurate, robust and selective RP-HPLC method has been developed for the estimation of Nimodipine impurity in bulk and formulation. The methanol: acetonitrile: water in proportion ... Prominence…
intra-operative local anesthesia and non-steroidal anti-inflammatory drugs respectively. A simple, rapid, selective and sensitive ultra pressure liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method has…
method by HPLC-ESI-MS-MS for the analysis of OTA. By engaging SRM (selective reaction monitor) mode mass spectrometry for four OTA most distinguish and strong ions ... billion concentration (ppb) with injection volume 8…
found to occur under sun light and thermal, were successfully resolved on a C18 column (5S, ODS 25 cm × 4.6 mm, 5μm), utilizing mobile phase of 0.025 M orthophospharic acid ... method was validated with respect to…
sensitive, selective and precise stability-indicating methods are presented for the determination of Acyclovir (ACV) in the presence of its degradate (Guanine). Method A depends on using first derivative ... performance…
estimation of Atenolol and Nitrendipine simultaneously in combined dosage form. A Phenomenox C-18 column having dimensions of 4.6×250 mm and particle size of 5 μm in isocratic mode ... rate of 1.5 ml/min and the eluents…
fractions in terms of cytotoxic activity against various cancer cell lines were subjected to column chromatography for isolation of pure compounds. Six triterpenes such as betulin, betulinic acid, lupeol, ursolic…
Alogliptin Benzoate. Separation was achieved with a Lux cellulose 2 (250×4.6mm, 5μm) column. The ratio of ethanol and diethyl amine in the mobile phase were optimized to obtain ... range of 100–102%. The method is…
waters Oasis HLB cartridge (1 cc, 30 mg). The column used was Hypurity C18 column (50 × 4.6 mm, 5 µm), the mobile phase was a combination of methanol water containing ... detection was performed on a triple guard…
avian IgY, monoclonal antibodies and lectins. Lectins are particularly well-suited to bind and selectively isolate certain glycan structures present in complex samples like biological ones. The lectin reversibly…
selective and short time consuming cost effective micellar high performance liquid chromatographic technique is created for the separation and simultaneous assay of two antiplatelet drugs, Rivaroxaban (RIV) with…
System was developed for this purpose. It includes the following parts: 1. A stream selection device to connect and monitor the source water and treated water using one instrument ... extract and concentrate the…
Escherichia coli. Recombinant RT was purified in native condition employing Ni-NTA affinity column. Purified RT showed a stable reverse transcriptase ac-tivity and a much stronger DNA polymerase activity…