linear, precise, and accurate RP-HPLC method was developed and validated for the simultaneous estimation of Rupatadine and Montelukast from bulk and formulations. Chromatographic separation was achieved isocratically…
formulations and enabled the determination of the drug in microgram quantities 0.5 to 3.0 mL for DP. No interference is observed from excipients and the validity of the method ... validity of the described procedure was…
methods are validated statistically and by recovery studies. The proposed methods are economical, sensitive and can be used for routine analysis of Eplerenone in bulk and tablet formulation
additives in formulations did not interfere. Statistical treatment of the experimental results indicates that the accuracy and precision of the methods are analytically acceptable. The validity of the methods
develop and validate a simple, rapid, accurate and economical UV Spectrophotometric method for determination of levofloxacin hemi hydrate in bulk and marketed formulation. In Water, the λmax of the drug ... were…
phase Ultra performance liquid chromatography method was developed and validated for the determination of lacosamide (LCM) and its related substances in bulk and pharmaceutical formulations. The separation of impurities…
reversed-phase liquid chromatography (RP-UPLC) method is validated for the determination of aliskiren in tablet dosage form. The LC method is carried out on a Waters Acquity ... showed that there is no interference of…
described for simultaneous determination of amoxicillin trihydrate and bromhexine hydrochloride from the combine formulation i.e. capsules. The separation of two drugs was achieved on a ZORBAX Eclips ... ZORBAX Eclips…
hematopoietic changes. The several herbal formulations derived from Ayurveda and its additional systems of medicine, either not yet to be scientifically validated or scientifically validated; that they have flavonoids…
Reverse Phase - HPLC) method has been developed for the estimation of Valsartan in tablet formulations. The separation was achieved on a X terra ,RP-18(100mm Х 4.6mm 5μm ... retention time of valsartan was found to be…
selective, precise and accurate High Performance Liquid Chromatographic Method for the analysis of Azithromycin in its formulations was developed and validated in the present study. The mobile phase consist…
analysis of cited drugs in pharmaceutical formulations. Recovery study was performed to confirm the accuracy of the methods. The methods were validated as per ICH guidelines
develop and validate simple, sensitive and specific spectrophotometric method for the determination of rifapentin, an anti-tubercular drug in pure form and in pharmaceutical formulations. UV-VISIBLE spectrophotometric…
HPLC method was developed for the estimation of quetiapine fumarate in bulk and pharmaceutical formulations. Quetiapine fumarate was chromatographed on Microsorb ... flow rate of 1.0 ml/min with detection at 292 nm. The…
simultaneous determination of Metoprolol Tartrate and Chlorthalidone in tablet dosage form is developed and validated. The chromatographic analysis was performed on a C 18column grace smart RP18 ... stavudine . The…
Assay method was developed for the ayurvedic formulation, the percentage purity was found to be 97.68 % w/v. The method was validated as per ICH guidelines and results were statistically ... 1μg/ml respectively. TLC…
bilayer tablet dosage form. The quantification was achieved by the first-order derivative spectroscopy method at 225 nm (zero cross point of Glimepiride) for pioglitazone and 248 nm (zero cross ... results of analysis…
doripenem of concentration 200μg/mL and 300μg/mL were used for method A and method B respectively. These methods were based on the formation of colored ion-ion association complex ... developed methods had been…
bulk and on tablet dosage formulation. The repeatability study was done for the precision of proposed method. All the results of analysis were validated according to the International Conference
analysis has been validated statistically and recovery studies carried out in the range of 80-120 % to confirm the accuracy of the proposed method. The relative standard deviation was found ... present result shows that…
Rapid and simple methods for determination diclofenac (DF) in both chitosan films and microsphere formulations using HPLC and UV-visible spectrophotometer were developed and validated. The HPLC assay was performed…
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.