column of 250 × 4.6 mm internal diameter, 5 μm particle size with mobile phase consisting of O.1 M ammonium acetate and methanol of HPLC grade in the ratio ... maintained at 1.2 ml/min. The effluents were monitored at…
Ascentis Express C18; 7.5cm x 4.6mm, 2.7µcolumn and mobile phase comprising of mixture of 0.1%Triethyl amine with pH adjusted to 3 with Ortho phosphoric acid ... column temperature is maintained at 50ºC and flow rate at…
bulk drug and tablet dosage form. The drug was separated using a mobile phase acetonitrile: water, (40:60 v/v) on an Agilent ... ambient temperature and detection was performed at 277 nm. The detector linearity was…
Azithromycin in tablet dosage form.Xterra RP 18 (250x4.6mm, 5μ particle size), with mobile phase consisting of ortho-phosphori acid: methanol 70:30 V/V was used. The flow rate ... were monitored at 205 nm. The retention…
PrincetoneSPHRE 100 C18 column (250mm X 4.6mm, 5µ), using a mobile phase consisting of Acetonitrile: Potassium dihydrogen phosphate (0.01M) adjusted to pH 7.0 with triethylamine, in the ratio ... flow rate of 1.0mL/min…
analysis was carried out using a phenomenax C-18, pre-packed column. A mobile phase containing a phosphate buffer (pH 5.5) : Methanol : Acetonitrile : Tri-ethylamine (40 : 40 : 20 : 1.5), with ... acid, was pumped at a…
assay procedure had been developed and validated for propranolol tablets stability samples. The mobile phase consisted of buffer(5.0 g Triethylamine /1000ml water pH 4.0 by HCOOH): acetonitrile ... carried out under…
assay procedure had been developed and validated for verapamil tablets stability samples. The mobile phase consisted of buffer (1.4g Na2HPO4/1000ml water pH 7.0 by H3PO4): acetonitrile ... carried out under ambient…
discourage developments using this approach. Simultaneous extraction and derivatization attainable through solid phase analytical derivatizations (SPAD) can overcome such complicating problems in sample preparations…
performed utilizing thermo C18 (4.6 mm×50 mm, 1.9 μm) column having a mobile phase comprising of 10 mM ammonium dihydrogen phosphate pH adjusted to 3.00 ± 0.02 with dilute orthophosphoric ... eluted components were…
achieved using a C18 column (250 mm × 4.6 mm, 5 μm) with a mobile phase comprising buffer (e.g., phosphate buffer, pH 3.0) and acetonitrile in a suitable ratio under isocratic ... flow rate was maintained at 1.0 mL/min…
18column grace smart RP18 (250×4.6 mm, 5 μm) in isocratic mode, the mobile phase consisted of methanol, acetonitrile and 0.05 M phosphate buffer (adjusted topH 4.5 with ortho-phosphoric ... flow rate of 1.0 mL/min and…
particle size) column in an isocratic mode with mobile phase containing phosphate buffer (adjusted to pH 4.8 with dilute othophosphoric acid, acetonitrile and methanol in the ratio ... flow rate of 1ml/min. The analyte…
achieved on Symmetry C18, 150mm x 4.6mm, 5μm particle diameter column. The mobile phase consisted of phosphate buffer (0.02M, pH:5.0±0.05 with dilute orthophosphoric acid) and acetonitrile ... ambient temperature. The…
150cm ×4.6mm I.D., 3μm particle size) in isocratic elution mode with the mobile phase consisting of 10mM Potassium dihydrogen ortho phosphate (pH:3.00): Acetonitrile in the ratio ... detection of eluent from the column…
shim-pack CLC-ODS column(25cm X 4.6mm, 5µm) and a mobile phase constituted of Buffer (850 ml of 0.05 (M) Citric acid monohydrate ... flow rate was 1 ml/min and the analyses performed using ultraviolet (UV) detector at a…
mixtures were separated on a C 18 reversed-phase column with an isocratic mobile phase consisting of 0.1% formic acid in acetonitrile and water ... quantification were performed using a mass spectrometer with a positive…
particle size in isocratic mode, with mobile phase comprising of 0.1% v/v phosphate buffer pH 3.0 ± 0.05, acetonitrile, methanol in the ratio ... flow rate was 1 mL/min and the detection was carried out by UV detector…
column (250mm×4.6mm, 5 μ m) maintained at 30°C and a mobile phase of 0.2 M tri fl uoroacetic acid water–acetonitrile ... uence of gas pressure and temperature of the drift tube in the detector on the detection response…
information about two colors. The conceptual model provides an intuitional picture of the in-phase and out-ofphase photon correlations and a complete quantum understanding about the which-path information ... Zhao, Sen…
BaBrCl:Eu, we directly observed dynamics of phase separation within the liquid phase as well as dynamics of liquid/solid interface and dopant segregation during crystal growth ... studies became possible with the recent…
excellentl y resolved peaks were obtained via an RP – C 18 column. The mobile phase (mixture of Buffer pH 3.0: Acetonitril e: Methanol) was pumped at a flow rate ... eluents were monitored by a uv-detector set up at 240…
C18Column (4.6 mm i.d. X 250mm, 5µm), Shimadzu LC-20AT ProminenceLiquid Chromatograph. The mobile phase composed of10 mM Phosphate buffer (pH3.0,adjusted with triethylamine): acetonitrile ... with the responses measured…
Phenomenex-ODS-3 (C-18) column (250 × 4.60 mm, 5 μm) with a mobile phase consisting of methanol:acetonitrile:15 mM potassium dihydrogen phosphate (pH 4) in the proportion ... rate of 1 ml/min. Detection was carried out…