selective and high throughput reverse phase liquid chromatographic method was developed for studying pharmacokinetics of tolterodine tartrate (TT) orodispersible tablets (ODT) in rats. Quantification is achieved by the…
drug was achieved on aisocratic Shimadzu prominence HPLC instrument on a Waters Xterra C18 column (250x4.6 mm, 5μ). Results: The method showed a linear response for concentration in the range ... Conclusion: The method…
pure and pharmaceutical dosage forms. . Chromatographic separation achieved isocratically on a ODS2 reverse phase column [Use Symmetry C18, 250 X 4.6mm, 5μ] utilizing a mobile phase of Methanol ... linearity, precision…
sensitive and selective liquid chromatographic-tandem mass spectrometric (LC-MS/MS) method was developed and validated for the trace analysis (> 1 ng/mL level) of 2-methyl-5-aminophenyl ... done on Inertsil C18 (150 mm…
high-quality chromatographic separation between the drug peaks by using a stainless steel analytical column Nucleosil, C18 (10 microm, 25x0.46 cm). The parametric statistics i.e. correlation coefficient ... less than…
separation was achieved on a LiChrosorb C18, 250 mm x 4.6 mm, 5 μm column at a detector wavelength of 274 nm. Isocratic regimen usage with ... impurities, in a short elution time (15 min). Analytical parameters…
variables were studied, % acetonitrile (ACN), % H3PO4 acid and mobile phase flow rate (FR). The selected responses were the analysis time (t) and the chromatographic resolution (Rs) among the most adjacent…
mL.min-1), The ranges used were selected based on previous studies in the literature. The CS used in these experiments had particle sizes of approximately 32 mesh. The evaluated response ... GCÃ?Â?GC/qMS. The first…
oxide(NPS) impedance biosensors with ordered nanopores have been demonstrated as highly sensitive and selective platform for label free electrical detection of biomolecules through an unique frequency dependent…
racemate was developed. (R)- and (S)Ketoprofen enantiomers were separated on a LiChrosorb NH2 column (250Ã?Â?4.6 mm, i.d 5 Ã?µm) at 20 Ã?°C, using 2-propanol ... Under these conditions, Ketoprofen enantiomers could be…
HRMS “Q-Exative” with H-ESI-interface (“Thermo Fisher Scientific”, Waltham, MA, USA) and columns “Kynetex” RP C8 50 × 3 mm × 2.6 μm type “core-shell” and “Poroshell” RP CE18 ... that the ionization in positive mode…
Solifenacin in bulk drugs. Separationwas achieved with aChiralpakAD(250mm× 4.6 mm, 10 µm) column. The ratio of n-hexane, ethanol and triethylamine in the mobile phase were optimized to obtain ... range of 96–100%. The…
selected chromatographic responses. Based on this responses analyses time (tR3), Capacity factor (k1) and selectivity (α) was optimized using Rotatable Central Composite Design (RCCD) and Response Surface Methodology…
simple, rapid, sensitive and selective liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and validated for the quantification of pravastatin in human plasma. Pravastatin-D3 was used…
concrete twisted peripheral building has been taken as an example to illustrate that the selection of adequate steel members and constructible connections, which leads to have a time reduction, high ... respectively…
groups to interact with these ions. The phosphonated derivative of polyethylenimine (PCPEI) showed high selectivity for U and As. The sulphonated derivative (SCPEI) showed high affinity towards ... filter systems…
trace amounts of drugs have, therefore, to be considered with special attention. A simple, selective, rapid, precise and economical reverse phase high performance liquid chromatographic method has been developed…
estimation of granisetron in tablet formulation. The separation was achieved by Luna C18 column and orthophosphoric acid buffer pH 7.5 and acetonitrile (70 : 30v/v) as mobile phase ... developed method was found to be…
topical application of 2 g to healthy volunteers. For this evaluation a new simple, selective and sensitive method for the determination of lidocaine and prilocaine in human plasma was developed ... chromatography…
chromatographic separation was performed on Xterra RP18,(150 mm × 4.6 mm and 3.5 μm) column using the mobile phase ACN: 0.1% formic acid (50:50 v/v). The internal standard ... Pibrentasvir. All of the parameters must be…
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.