families of orthogonal polynomials in mathematical chemistry, mathematical physics, probability theory, differential equations, combinatorics etc. One of the simplest ways to construct them is through their generating…
particular reactivity pattern to them.Since functional groups on TSILs are generally heteroatom-based, the challenge is to develop highly efficient, atom-economical and orthogonal methodologies, such as "click"…
using multi-trait and random regression models on Legendre polynomials and B-spline functions. A total of 87,712 weight records from 8144 females were used, recorded every three months ... growth trends were modeled…
known that a function in 2 L R can be represented by its wavelet expansion with convergence in 2 L R –norm. But the case is different ... norm. In this paper we shall discuss the convergence of non–orthogonal…
alloy products as a function of the amount of nickel content, the immersion time and the temperature. This mathematical model is developed based on orthogonal test and regression analysis
Higher-Order-Structure (HOS) has become a major investigation tool for establishing Structure-Function relationship. Differences in HOS provides potential clues to any observed biological and/or immunological…
amino acids that are genetically encoded. Using evolved orthogonal aminoacyl-tRNA synthetase-nonsense suppressor tRNA pairs, noncanonical amino acids with bioorthogonal functional groups such as azide, alkyne…
functional activities. Strategies for primary and higher order structure determination will be discussed particularly for antibodies where their size and complexity requires LC/MS/MS approaches. Appropriate orthogonal…
mobile WiMAX air interface adopts Orthogonal Frequency Division Multiple Access (OFDMA) as multiple access technique for its uplink and downlink transmission. All OFDMA based systems, including mobile WiMAX, experience…
functional activities. • Strategies for primary and higher order structure determination will be discussed particularly for antibodies where their size and complexity requires LC/MS/MS approaches. Appropriate orthogonal…
same time, the development of stateof- the-art orthogonal analytical methods has enabled a better understanding of the structure and structure– function relationship of biotherapeutics. An important evolution
time, the development of state-of-the-art orthogonal analytical methods has enabled a better understanding of the structure and structure–function relationship of biotherapeutics. Observations: In recent years, many
combinations of unnatural amino acid incorporation and bio-orthogonal click chemistries to post-translationally attach fluorescent reporters, carbohydrates, or other functional groups onto purified target proteins…
like orbitals are eigen functions of Fock operators that contain nuclear coulombic and exchange lattice potentials plus lattice projection operators enforcing the ion-lattice orthogonality. These lattice-consistent…
time, the development of state-of-the-art orthogonal analytical methods has enabled a better understanding of the structure and structure-function relationship of biotherapeutics. Hence, we suggest here that
possible to find a regression curve of many random signals if their probability distribution function (PDF) is not known? This problem can be solved if we replace a priori supposition ... methods associated with…
function. The training samples are generated from the pixels value of 8X8 blocks of different standard images with varied pixel orientation. Further, the dictionary elements are encoded using orthogonal matching
expression of orthogonal continuous chaos frequency modulation signal (OCCFMS) is given, autocorrelation and quasi-orthogonal property is analyzed, and proposes a progressive chaotic particle swarm optimization…
assess the structural and functional analysis of the biosimilars. In performing this assessment, the FDA emphasizes the added use of “orthogonal methods” and “fingerprint-like methods”. These latter methods
modulation M-OAM (Orthogonal Amplitude Modulation) which is based on the use of original mathematical tools called Modified Gegenbauer function (MGF) increases the data rate flow and enhances the robustness
optics integration on a chip or a sensing device replacing various functions of an optical microscope system. For example, a grating waveguide integrated on a chip can generate similar evanescence ... resolution…
Improved efforts are necessary to define the functional product of cancer mutations currently being revealed through large- scale sequencing efforts. Using genome-scale pooled shRNA screening technology, we mapped…
field lines. And an additional function which varies along the magnetic field lines the magnetohydrodynamic metage μ (however, its surfaces are generally not orthogonal to the field lines). We further
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.