wharf are working, and most of them are harmful to people. Since the VOCs detector usually matches given kinds of gases, if the exact kind of gases is undefined ... based on the portable GC-MS technology. The VOCs are…
simple capillary gas chromatography method using a flame ionization detector has been developed and validated for the quantitative determination of trace analysis of 2, 2’-Azobis-Iso-Butyro-Nitrile (AIBN ... long with…
order harmonics generated by the laser-irradiated plasma surface, complete reconstruction using the spectral phase interferometry for direct electric-field reconstruction (SPIDER) method is studied in detail with…
phase microextraction (SPME), dispersion-liquid microextraction (DLLME) and packed sorbent microextraction (MEPS) and bulk phase sorption extraction (FPSE). These techniques represent the rapid development of sample…
column (150 X 4.6 mm i.d., particle size 3.5μ).The mobile phase consisted of Pentane sulphonic acid sodium salt mono hydrate, add 1ml of Perchloric acid and adjust ... ambient temperature. The detection was carried out…
respectively. Quantification was achieved with Photodiode array (PDA) detector at 239 nm over the concentration range of 0.5-5 μg/mL for each, with recoveries in the range ... toluene: acetone: glacial acetic acid…
overall run time was 10 min. and the flow rate of the mobile phase was 1.0 mL/min. with UV detection at 220 nm. 20 μL of sample was injected ... Shimadzu Model CBM-20A/20 Alite, equipped with SPD M20A prominence…
overall run time was 10 min. and the flow rate of the mobile phase was 0.8 mL/ min. with UV detection at 215 nm. 20 μL of sample was injected ... Shimadzu Model CBM-20A/20 Alite, equipped with SPD M20A prominence…
Column, 250x4.6 mm, column with 5 μm particle sizes and the Mobile Phase consisting of 0.02M Potassium Dihydrogen Phosphate pH: 3.2 adjusted with Methanol & Acetonitrile in ratio ... effluents were monitored at 242 nm…
precoated silica gel 60 F254 (0.2 mm thickness) on aluminium sheets and a mobile phase Ethyl acetate: 1, 4 Dioxane: Methanol: 25% Ammonia in the ratio ... Telmisartan and Amlodipine respectively. The plate was scanned…
Symmetry shield RP-18, 250 mm x 4.6 mm, 5μm with a isocratic mobile phase composed of Buffer: mixture of solvent in the ratio of 10:90 % v/v (mixture ... maintained at 40°C and the detection was carried out using a PDA…
simple and rapid ultraperformance liquid chromatography (UPLC) method with photodiode array (PDA) detector has been developed. Further confirmation was performed by electrospray ionization mass spectrometry (ESI-MS) for…
column and gradient elution for both the methods. The aqueous mobile phase contained 0.02 M phosphate buffer adjusted to pH 3.5 with hexane-1-sulphonic acid, sodium salt ... carried out in the range of 200 to 600 nm…
simple, rapid, accurate and precise reverse phase-high performance liquid chromatographic (RP-HPLC) method has been developed and validated for the simultaneous determination of Terbutaline sulphate and Guaiphenesin in…
detectors with space heritage (two detectors assemblies, one with CZT and another of BGO detectors), and a code mask at front of the instrument, provide imaging capabilities for TGF location ... envelope budget are the…
drops. An Alltech Spherisorb C8 150 mm x 4.6 mm, 5 μ with mobile phase consisting of Water, methanol and glacial acetic acid were mixed in the ratio ... retention time of the Ketorolac peak is about 3 minutes. The…
detectors with space heritage (two detectors assemblies, one with CZT and another of BGO detectors), and a code mask at front of the instrument, provide imaging capabilities for TGF location ... envelope budget are the…
Kinetex C-18 100A (5 μ, 250×4.6 mm) column. The initial mobile phase composition used was acetonitrile and water in the ratio ... ilaprazole in marketed tablet formulation. The detection was carried at 305 nm using PDA…
were eluted with a mobile phase of 0.03 M SDS/7% 1-butanol/0.02 M oxalic acid/NaOH at pH 2.5. This method provided average recoveries ... linearity for the four TCs was determined by high performance liquid…
HPLC system with Waters 2487 Dual wavelength Absorbance detector and Waters 2998 Photodiode Array Detector using a stainless steel column of dimension 15 cm x 4.6 mm , packed with octadecylsilane ... Acetic Acid and 5…
plasma sample was extracted using chloroform:formic acid (4.0:0.4, v/v). The mobile phase used consists of methanol: chloroform: ammonia solution [25%] (8.5: 1: 0.4 v/v/v), having ... DICLO respectively. Densitometric…
challenge is the realization of integrated structures as a powerful technology for “packing” sources, detectors, electronics and optics into single and low costs platforms. In particular MIR and THz spectral ... Cancio…
exchange HPLC. For this purpose, its key parameters were estimated as the followings: stationary phase – polymethylamidopropylmethacrylamide; column PRP-X600 AE, 4.6 x 150.0mm, 5.0 particles, 1.6 meq/mL (Hamilton…
simple, rapid and precise reversed-phase liquid chromatographic method is developed for simultaneous determination of Atorvastatin, Ezetimibe and Fenofibrate in their ternary mixture of commercial pharmaceutical…
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.