ambient temperature. The analytes were monitored by PDA detector at 206 nm. The method was validated for specificity, precision, linearity, and accuracy. The average recoveries for RAST were ... present work has been…
Analytical methods development must be validated to provide reliable data for regulatory submissions. These methods are essential for a number of purposes, including testing for quality control release, testing…
process development and validation of drug substances. The steps involved in the method development and analytical validation was discussed, an advantage over the method was explained elaborately
simple, precise, accurate and rapid high performance thin layer chromatographic method has been developed and validated for the simultaneous estimation of two anti-diabetic drugs, sitagliptin and metformin hydrochloride…
positive electron spry ionization mode (mass-to-charge ratio (m/z):197). The method was fully validated using the parameters such as specificity, linearity, limit of detection and quantification, precision
Nordihydroguaiaretic acid in respective solvents. Nordihydroguaiaretic acid obeys the beer lamberts’ law. Method is validated according to ICH guideline and carried out for analysis of Nordihydroguaiaretic acid
sensitive, selective and precise high performance liquid chromatographic method has been developed and validated for the simultaneous determination of Dosulepin and Methylcobalamin both as a bulk drug and in formulation…
detection and quantitation of 0.023 and 0.070μg/ml for Hydrochlorothiazide The method was validated for linearity, range, precision, accuracy, specificity, selectivity and intermediate precision
water samples were collected in predetermined intervals and analyzed by a validated HPLC-UV. The method has the limit of quantification 0.01 μg/mL. The influence of cations
extracts were cleaned using florisil and analysed for azoles using GC-MS. The method was validated in fish samples spiked with investigated compounds at different concentration levels ... between 85-105% with a relative…
chain reaction was performed to validate these differentially expressed genes screened by the sequencing approach, and sufficient consistency was observed between the two methods. These findings strongly support that…
inhaler and compare the baseline outcomes with a similar study at Al-Ahsa region. Method: We approach 96 pharmacies in Al Qassim region as mock patient (Investigator). The investigator asks ... about proper inhalation…
validated to determine the pharmacokinetic profile of triamcinolone acetonide in silicone oil and aqueous humor of rabbits? eyes submitted to the pars plana vitrectomy surgery. The method was successfully applied
identified thus to be related to inappropriate medication use and inappropriate prescribing. Methods: This study is conducted using Prospective Cross Sectional study design as hospitalized elderly patients aged 65 years…
surveillance is essential for healthcare facilities due to the continued increase in reporting requirements. Methods : Stanford Hospital, a 583-bed adult tertiary care center, utilized their electronic medical record…
Government Area, Osun State, Southwest Nigeria. Methods: A cross sectional descriptive study of all primary schools in the area was done using a validated healthful school environment checklist. Data
estimation of Balsalazide in bulk and Capsule dosage form and the method was proposed for the validation for the parameters like accuracy, precision, linearity, range, robustness, ruggedness, % of recovery ... limit of…
encountered by practicing emergency physicians in providing palliative care in Puerto Rican Emergency Departments. Methods: A survey was administered to physicians attending the American College of Emergency Physicians…
micro-costing study was conducted on quality control, from the sampling to the validation of the results. Among 39 cytotoxic drugs, 11 were sampled which enabled to avoid a mean ... Costs were estimated at 4USD and 7USD…
from 10 to 60μg/ml of Raltegravir with correlation coefficient 0.999. The proposed method was validated as per ICH Q2 (R1) guidelines for precision, linearity, accuracy and recovery. The limit ... mlrespectively by…
decrease in absorbance measured at 319 nm using the experiment as a blank. Method (B) involves the addition of a known excess of ceric (IV) sulphate to drugs in acid ... Ramipril. The validity of these methods have been…
rate was 0.4 ml/min. UV detection was performed at 254 nm. This method was validated following ICH guidelines. All parabens were separated within 5 minutes
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.