detector was developed. The chromatographic peaks of the eight organic acids were successfully identified by comparing their retention times and UV spectra with reference standards. Method validation was performed…
utilized to inhibit the synthesis of Leishmania RNA. The conditions defined for development of the chromatographic analysis of dog plasma samples by utilizing the mobile phase of the HPLC ... Acyclovir was utilized as…
newly developed micellar liquid chromatographic analysis technique was utilized for the determination of Terbinafine HCl (TRH). A 150 mm × 4.6 mm i.d., Shim-pack Cyanopropyl-bonded stationary phase was used…
method was developed to determine the oil and grease in water by HPLC-Vis fluorescence technique. Ultrasonication liquid-liquid extraction method was applied by using 1 ml of toluene ... water. The analysis was carried…
capsule dosage form (325 mg and 30 mg) by selecting chromatographic parameters. The UPLC method was developed using 2.1 × 50 mm, reverse phase C18 column (Acquity UPLC ethylene bridge hybrid
simple, rapid, sensitive and selective liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and validated for the quantification of pravastatin in human plasma. Pravastatin-D3 was used…
almost 14% bioavability absolutely. The aim of this study is to develop and validate an analytical method for oral delivery of AtrCa in pharmaceutical dosage form. The HPLC system consisted ... found 1.30 μg/mL. In…
Three sensitive and validated chromatographic methods were developed for determination of Agomelatine (AGO) in the presence of its degradation products in drug substance and drug product. The first and second
Reversed Phase High Performance Liquid Chromatographic (RP-HPLC) method using symmetry C18, 5.0 mm column was developed for the determination of Efonidipine Hydrochloride Ethanolate (EFD). The mobile phase acetonitrile
innovative, quick and easy reversed phase high performance liquid chromatographic method is elaborated and authenticated for the quantitative determination of caroverine in pharmaceutical bulk material and tablets…
High-Performance Liquid Chromatography) method was developed for the simultaneous determination of Eperisone Hydrochloride and Diclofenac Sodium in capsule dosage form. After that optimization good chromatographic…
pyridine was developed and validated. Separation was achieved on HP-Innowax polyethylene glycol gas chromatographic column (30 m × 250 μm × 0.25 μm) using Agilent 7890B gas chromatograph equipped with Agilent ... active…
sensitive, selective, precise and stability indicating high-performance thin layer chromatographic method (HPTLC) was developed and validated for analysis of eugenol from methanolic extract of Myristica fragrans seed…
recombinant human growth hormone (rhGH), has been developed using pulsed electrochemical detection (PED), following ion Chromatographic separation. A Dionex-500 ion chromatograph coupled with an electrochemical detector…
developed for the detection of bacterial resistance due to enzymatic degradation of Ã?²-lactam antibiotics with the goal of designing a liquid chromatography âÂ?Â? tandem mass spectrometry acquisition method…
addition, the high dynamic capacity of new developed gels provided a satisfactory retention of the peptide/protein at elevated temperature of the chromatographic process. These both factors allowed the implement…
rapid, novel, and efficient stability indicating reverse-phase high performance liquid chromatographic (RPHPLC) analytical method was developed and validated for the determination of four female hormones: Progesterone…
simple, specific, sensitive and rapid LC-ESI-MS/MS method has been developed and validated for the quantification of GSK-199 in mice plasma using warfarin as an internal standard ... respectively. The total…
performance liquid chromatography with diode array detector (RP-HPLC-DAD) related substances analytical method has been developed, optimized and validated for the determination of degradation products and process…
precise method was developed using HPLC-MS/MS to quantify mycophenolic acid in human plasma. Mycophenolic acid-D3 was used as internal standard. Sample preparation involved protein precipitation. Chromatographic…
heart failure, and heart attacks. Numerous analytical methods have been developed for the determination of lisinopril. These methods include Chromatographic methods, UV spectrophotometric methods, IR, Polarographic…
rapid and sensitive LC-MS/MS method has been developed and fully validated for simultaneous quantification of aspirin (ASP), salicylic acid (SLA), rosuvastatin (RVT), rosuvastatin lactone (RVL) and N-desmethyl…
selective liquid chromatography-tandem mass spectrometric (UPLC-MS/MS) analytical method based on protein precipitation was developed and validated for analysis of Adefovir in human plasma. Adefovir-d4 was used…
specific and sensitive high-performance liquid chromatographic method for the simultaneous determination of rabeprazole sodium and domperidone in bulk drug and capsules was developed. Ranitidine hydrochloride was used…
investigation was to develop a simple, rapid and accurate RP-HPLC method to determine assay of Metformin Hydrochloride And Empagliflozin in Bulk and synthetic mixture. The chromatographic separation was performed
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.