concentration range of 2.0 -7.0 ìg/ml in all themethods. All the methods were validated by following the analytical performance parameters suggested by International Conference onHarmonization (ICH) guidelines.All…
concentration range of 2 -12 ìg/ml in all three methods. All the methods were validated by following the analytical performance parameters suggested by International Conference on Harmonization (ICH) guidelines.All…
reverse phase HPLC method was developed and validated for the simultaneous determination of two antiviral drugs viz. lopinavir and ritonavir. Chromatographywas carried out onC18 Column, Inertsil ... themethod was…
accurate and sensitive spectrophotometric methods have been developed and validated for simultaneous determination of cinnarizine (CINN) and dimenhydrinate (DIM) in binary mixture without previous separation. The first…
HPLC method for stability indicating determination of biperiden hydrochloride (BIPER) in presence of its oxidative and /or acid degradation products, was developed, optimized, validated and appiled either in tablets…
treatment of hyperlipidemia.Arapid, simple and sensitive liquid chromatography–tandem mass spectrometry (LC-MS/MS)method for determination of EZB andATVC in spiked human plasma has been developed and validated.Plasma…
determination of chemical compounds. The present paper describes a simple, highly sensitive and validated UV- spectrophotometric method for the estimation of risperidone (RSP) in both pure and in pharmaceutical…
using the spectrum of 20 µg ml-1 (degradation) as a divisor. The third method is mean centering of ratio spectra withmeasurement at 306.4 nm.The fourthmethod depends on TLCdensitometry using ... were successfully…
Simple, rapid, accurate and precise spectrophotometric methods have been developed and subsequently validated for simultaneous determination of telmisartan (I) and bisoprolol fumarate (II), separately, in binary…
results are statistically compared with those obtained by the reference UV method and validated by recovery studies. The results are found satisfactory and reproducible. No interference was observed from
objective of the current study was to develop a validated, simple, precise, stability indicating reverse phase HPLC method for the determination of Dabigatran etexilate mesylate in bulk drug and dosage ... accuracy and…
present work describes development and validation of stability indicating HPTLC-densitometric and HPLC methods for quantitative analysis of cefepime in bulk and injection dosage form. InHPTLC, separation was performed
derivative spectrumhas the maximumamplitude in negative valley at 249.0nmhence the second derivative method was validated bymeasuring amplititudes at 249.0nm. Standard deviation and percent of relative standard…
concentrate three kinds of isoquinoline alkaloids in which measured human urine by HPLC. The method affords significant simplification of the conventional CPE procedures without requiring specialized apparatus, thereby…
Themethod was optimised based on the basis of solubility of Benzyl bromide. The method was validated as per ICH guideline in terms of LOD, LOQ,Method precision, accuracy and specificity
Four different stability indicating assay methods were developed and validated for the determination of tadalafil in the presence of its degradation product. The first and second method was based
sensitive, reproducible, and rapid stability indicating RP-HPLC method was developed and subsequently validated for simultaneous determination ofmoexipril (MOX), its activemetabolitemoexiprilat (MOXT), and…
measurement at 302.2 nm and 338.8 nm for TELM and HCT respectively. The fourth method is an isocratic reversedphase HPLC procedure using amobile phase 0.05Mammoniumacetate (pH 6.0): acetonitrile:methanol ... were…
determination of Ornidazole, in pure and pharmaceutical formulations,has been developed and validated. The proposed method is based on the reduction of the nitro group to amino group ... obeyed in the concentration…
analyzer.Method is sensitive, precise, accurate and linear as per the parameters conducted for the validation activity. Calibration curve showed good linearity over the concentration range ... respectively. Also method…
statistically compared with those obtained by the reported UV reference method (methanol as solvent ë max at 231nm) and validated by recovery studies. The results are found satisfactory and reproducible
compounds entry in food chain. So aimof the present study was to optimize and validate the analytical parameters for analysis of chloramphenicol residues by liquid chromatography tandem mass spectrometry ... step using…
Newhigh performance liquid chromatographic (HPLC) and derivative spectrophotometric methods have been developed and validated for the simultaneous determination of tioconazole and benzyl alcohol in bulk and cream dosage…
administration of biomolecules like proteins. The purpose of this work is to validate a novel formulation method by a phase separation phenomenon using the non-toxic solvent glycofurol
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.