adding combined BPM + ABA, but the reverse was observed for water consumptive use, crop coefficient and beneficiary factor. The highest values of fig fruit yeild,water use efficiency andwater economywere ... Likewise…
competing for ionexchange sites in naturally occurring clinoptilolite.The percentage adsorption and distribution coefficients (Kd) were determined for the adsorption system as a function of sorbate concentration…
high genetic variability among the germplasm. Dice similarity based on the DNA markers revealed coefficient value ranging from 1.000 (perfect match) to 0.624 (divergent). Clustering by un-weighted group method
method was found to be 0-30ïÂÂg/ml with regression coefficient of 0.99921. The detection limit and quantitation limitwere 0.0024ïÂÂg/ml and 0.0073ïÂÂg
linear in the range 0.02-1.92 ïÂÂg/ml, and intra- and inter- run coefficients of variationwere ï‚£ 5.3%and ï‚£ 10.1%, respectively. Extraction recovery and intra
over the range of 0.2-20ïÂÂg/ml, and the intraand inter-run coefficient of variationswere ï‚£ 5.2%and ï‚£ 6.7%, respectively. Extraction recovery and intra
constructed in the concentration range of 0.1 to 200 ïÂÂg/mL with correlation coefficient 0.9998. The detailed study of various foreign ions made the method more sensitive and selective
found to be greater than 4.0. Regression analysis shows an r value (correlation coefficient) of greater than 0.9999 for Efavirenz enantiomer. This method was capable to detect enantiomeric impurity
found to be greater than 4.0. Regression analysis shows an r value (correlation coefficient) of greater than 0.9999 for Stavudine and it’s all the two impurities. This method
min.The retention time of Losartan 5.1 min, the total run time 6 min.Linearity correlation coefficients (r2) curve was 0.999818,calibraction range 10-1000ng/mL.TheLLOQ of Losartan 10 Pico gram
linearly with increase in concentration of FLH, which was corroborated by the calculated correlation coefficient values (0.9996 and 0.9995). The systems obeyed Beer’s law in the range
were found to be greater than 2.0. Regression analysis shows an r2 value (correlation coefficient) of greater than 0.99 for ZaleplonAnd it’s all the degradant impurities. This method
found to be greater than 3.0. Regression analysis shows an r value (correlation coefficient) of greater than 0.999 for Ramipril and it’s all the four impurities. This method
curve produced a high Pearson r correlation of 0.9922 (very high correlation),with a coefficient of determination (R2) at 0.9845. Percent recovery of quinine was 93 % to 115 % with standard
method is linear over the concentration range of 50-400 mcg/ml and the coefficient of determination were >0.999 with a relative standard deviation of 0.001 %. The average recovery
themethod was established in the range 50 ng - 150 ng/ mlwith a correlation coefficient of 0.9943 The limit of detection of felodipine was 25 ng/ml and limit of quantification ... Excellent precision was evident with a…
trimethyl ammonium bromide (CTAB) have been studied in aqueous solution spectroscopically. The molar absorptivity coefficient ‘ïÂ¥’ has been determined for the aqueous micellar solutions both in absence
retention time of Carbamazepine 3.9 min, the total run time 6 mints. Linearity correlation coefficients (r2) curvewas 0.998070, calibraction range 10-1000ng/mL.TheLLOQ of Carbamazepine 10 Pico gram
December 2004. The mean age (Xort), percent agreement (PA), average percent error (APE) and coefficient of variation (CV) were used to compare the reliability of bony structures. Similar results were
factor 4 (non-cardiovascular complications) were correlated with factor 1 (diabetes) their correlation coefficients were 0.90, 0.94, and 0.71 respectively. This implies that knowledge of diabetes self care and knowledge
program SPSS 13. The self-coherence reliability of the study was tested on the coefficient alfa (Cronbach’s a), which was equal to 0,71. Results: The participants who finally
scanning calo rimetry (DSC), X-ray diffraction (XRD), N-octanol/water Par ti- tion Coefficient were tested. The concentrations of oxymatrine after oral administration of oxymatrine– phos- pholipids complex
Test, Kruskal-Wallis test) were used. Correlations were calculated using Spearman rank correlation coefficients. Probability values < 0.05 were considered significant. Results: Index of proliferative activity of…
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.