tablet formulation. Chromatographic separation of the two drugs was achieved on a Phenomenex column (200mm×4.6 mm, 5μm). The mobile phase consisting of a mixture of 0.1 M phosphate buffer ... accuracy, precision and…
estimation of silodosin and dutasteride capsules. The analysis was carried out using Unison C8 column (250 mm x 4.6, 5 μm particle size) at 40°C temperature using mobile phase ... current study showed that the developed…
Khan, M.S., Lee, S., Mesfin, G & Moonyong, L.(2015).”Knowledge inspired investigation of selected parameters on energy consumption in nitrogen single and dual expander processes of natural gas liquefaction”. Journal…
essential for their ultimate identification. For instance, Trappe has given “Eluotropic Series” for column chromatography, where the solvents used can be based on accordance to their eluting effect. “Snyder triangle…
based on the separation of the two drugs in reversed-phase mode using C18 column (150 mm x 4.6 mm I.D., 5 μ particle size). The optimum mobile phase consisted ... Febuxostat and 0.03 for Ketorolac. The proposed method…
respectively. The flow rate was 0.8 mL/min with column temperature of 45°C and detection wavelength at 277 nm. The developed method was validated as per ICH guidelines with ... Conclusion: The developed method was found…
assay. The samples were eluted in an isocratic method using an inertsil ODS column (4.6 mm × 250 mm with a particle size of 5 μ) with a mobile phase consisting ... respectively. The method was quantitatively evaluated…
dosage form. Separation was achieved under optimized chromatographic condition on a Welchrom C18 isocratic column, (250 mm × 4.6 mm i.d., particle size 5 μm, maintained at ambient temperature).The mobile ... percentage…
lasers combining fractional technology with deep ablative effect of CO2 laser. Micro-ablative laser columns penetrate deep into the skin with a maximum depth 2.5 mm. The wavelength ... opportunity for skin rejuvenation…
consisted of [51.50%] acetonitrile and [48.50%] 0.025 mM ammonium acetate with pH of 8, column of separation was C8 at temperature of 40°C using injection volume ... accuracy % range [99.35-103.99]. The coefficient of…
flow rate was investigated. Separation was developed on a reverse-phase Gemini C18 column (150mm×4.6mm i.d., 5μm particle size), using a mixture of methanol (MET): water (0.05% Triethylamine ... precisions at four…
neurotransmitter, with receptors they are involved in many functions in human. Rats were selected to simulate smokers, and distributions of nicotine and cotinine in tooth, alveolar bone and brain ... Sciex 5500 LC-MS/MS…
using Rhodamine B agar medium. The maximum enzyme producing strain, Bacillus subterraneus TNUS15 was selected and an empirical model was developed for the enhanced yield of enzyme production by various ... crude enzyme…
hyperactivity disorder ADHD, learning problems). The EU project DENAMIC investigates harmful neurotoxic effects of selected compounds in order to reveal possible links between exposure to the compound mixtures…
separated exclusively according to their composition or architecture. LC LC exhibits remarkable separation selectivity, as well as high sample capacity and reasonable sample recovery. Moreover LC LC is highly robust…
Target-based metabolomics is focused on a subset of metabolites selected from metabolic pathways of interest to measure changes in concentrations of endogenous metabolites. Metabolomics is a valuable tool…
perform and replicate with high reliability. For the RP-HPLC analysis, a thermosil C18 column (4.6 x 250 mm, 5 μm) is used with a mobile phase comprising ... reliable, quick, exact, and easy to use. Using this simple…
Hydrochlorothiazide from bulk and formulations. Chromatographic separation achieved isocratically on ODS hypersil C18 column (5 μm, 250 mm × 4.6 mm) and micellar mobile phase of 0.07M sodium dodecyl sulfate…
ethyl ether: dichloromethane (70:30) subsequently separated on an Ace 5 C18 column (100 mm × 4.6 mm, 5 µm) using methanol:0.1% formic acid in water ... method was fully validated for all the other parameters such as…
Three sensitive and selective methods were developed and validated as stability indicating methods for the determination of amylocaine HCl in presence of its degradation product. The first method is based ... method is…
highly selective and rapid method has been established for chromium(VI) sorption from aqueous HCl media using tetrazolium chloride [TZ+.Cl-]-nanoparticles (Ag NPs) chemically impregnated polyurethane foams (PUFs) solid…
achieved with an phenomenex aeris wide pore XB-C8 (100 × 4.6 mm) 3.6 μm column thermostated at 40°C with a mobile phase containing gradient program with Pump A: (Acetonitrile ... well within the acceptance limits. The…
Extractions (CSCEs), which are cannabis extracts obtained using polar solvents and analysed using Liquid column Chromatography combined with Mass Spectrometry (LC/MS). However, the complex nature of cannabis compounds…
environment concern, which is not well understood. The transport of selenite in loessial soil columns was studied using a miscible displacement technique under various flow rates and influent concentrations…
were prepared by maceration in organic solvents. Fractionation of plant extract was performed by column chromatography and the structures of isolated compounds (emodin, 3-geranyloxyemodin, 2-geranylemodin) were…
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.